Evaluation of Parameters Influencing Hexavalent Chromium Mist Sampling: A Full Factorial Design

نویسندگان

  • Aram Tirgar School of Public Health, Medical Sciences / University of Tehran, Tehran, I.R. IRAN
  • Farhang Akbar Kanzadeh Medical University of Ohio at Toledo, P.O. Box 43614 Ohio, U.S.A
  • Farideh Golbabaei School of Public Health, Medical Sciences / University of Tehran, Tehran, I.R. IRAN
  • Javad Hamedi School of Chemistry, University of Tehran, P.O. Box 14155-8464 Tehran, I.R. IRAN
  • Keramat Nourijelyani School of Public Health, Medical Sciences / University of Tehran, Tehran, I.R. IRAN
  • Mohammad Reza Ganjali School of Chemistry, University of Tehran, P.O. Box 14155-8464 Tehran, I.R. IRAN
  • Sayed Jamaleddin Shahtaheri, School of Public Health, Center for Environmental Research, Medical Sciences / University of Tehran, Tehran, I.R. IRAN
چکیده مقاله:

A chromium electroplating bath with the ability to produce homogenous mist was used to evaluate parameters influencing hexavalent chromium (Cr+6) mist sampling methods. The results of 48 Cr+6mist samples collected using the U.S. National Institute for Occupational Safety and Health method 7600showed that Cr+6concentration was higher: (1) For sampling by closed-face filter cassettes than for sampling by open-face filter cassettes (P <0.001); (2) for samples collected at 35 cm above the electroplating solution surface than for samples collected at 50 cm (P <0.001); (3) for sampling duration of 30 minutes than for sampling duration of 180 minutes (P <0.001); and, (4) for samples extracted immediately after sampling than for samples with delayed extraction (24 hours after sampling) (P <0.001). It is concluded that the accuracy of Cr+6 mist sampling in electroplating shops will be enhanced when: (1) closed-face filter cassette is used to prevent liquid splash contamination; (2) the recommended sampling height is 35 cm above the solution surface; (3) the sampling duration is short--approximately 30 minutes; and, (4) the extraction of the Cr+6 sample is performed as soon as the sampling is completed.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

evaluation of parameters influencing hexavalent chromium mist sampling: a full factorial design

a chromium electroplating bath with the ability to produce homogenous mist was used to evaluate parameters influencing hexavalent chromium (cr+6) mist sampling methods. the results of 48 cr+6mist samples collected using the u.s. national institute for occupational safety and health method 7600showed that cr+6concentration was higher: (1) for sampling by closed-face filter cassettes than for sam...

متن کامل

Design and Performance of Chromium Mist Generator

O gerador de névoa crômica homogênea é uma ferramenta essencial para pesquisas e avaliações científicas, sobre a poluição do ar e seus sistemas de controle. O objetivo desta pesquisa foi projetar e construir um gerador de névoa de cromo e estudar alguns fatores, como altura de amostragem e distâncias entre amostras, em amostragens lado a lado, com o método de amostragem de névoa crômica. O gera...

متن کامل

Development and evaluation of orally disintegrating tablets of Pramipexole using full factorial design

Pramipexole is the mostly prescribed drug in patients with Parkinson disease. The incidence of Parkinson disease is related to aging and mostly developed in elderly people with difficulty in swallowing or dysphagia. In the current study we aimed to develop an orally fast disintegrating tablet (ODT) of pramipexole as a preferable alternative in geriatric patients. Hence, the fast disintegration ...

متن کامل

Automated Ground-Water Sampling and Analysis of Hexavalent Chromium using a “Universal” Sampling/Analytical System

The capabilities of a “universal platform” for the deployment of analytical sensors in the field for long-term monitoring of environmental contaminants were expanded in this investigation. The platform was previously used to monitor trichloroethene in monitoring wells and at groundwater treatment systems (1,2). The platform was interfaced with chromium (VI) and conductivity analytical systems t...

متن کامل

Carcinogenicity of hexavalent chromium.

Hexavalent chromium (Cr(VI)), a commonly used industrial metal, is a well known human lung carcinogen. Epidemiology and animal studies suggest that the particulate Cr(VI) compounds, specifically the water insoluble compounds, are the more potent carcinogens; however, the carcinogenic mechanism remains unknown. Here we summarize recent Cr(VI)-induced human tumour, in vivo, cell culture and in vi...

متن کامل

Microbial Reduction of Hexavalent Chromium

Publication 1. A. Manceau et al, “Quantitative Zn speciation in smelter-contaminated soils by EXAFS spectroscopy,” Am. J. Sci. (in press, 2000). Figure 3 (top) Soil samples were taken at several depths from a contaminated site. (bottom) Model compounds derived from polarized-EXAFS data at the ESRF and μ-EXAFS data at the ALS provide a good fit with powder-EXAFS spectra from a soil sample, there...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 26  شماره 4

صفحات  115- 121

تاریخ انتشار 2007-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023