Evaluation of Gonadal Exposure Dose in Long Bone Plain Radiography for Radiation Protection

نویسندگان

  • Jina Shim Department of Bio-Convergence Engineering, Korea university, Seoul, Republic of Korea
  • Myonggeun Yoon Department of Bio-Convergence Engineering, Korea University, Seoul, Republic of Korea
  • Youngjin Lee Department of Radiological Science, Gachon University, Incheon, Republic of Korea
چکیده مقاله:

Introduction: Long bone examination in standing position, as one of the diagnostic methods in plain radiography, is most commonly used in the field of medical diagnosis, especially leg length discrepancy. However, with regard to this examination, reproductive organs are exposed to radiation as they are placed in the adjacent area to the long bone. Due to the sensitivity of gonads to radiation, their exposure must be kept as minimal as possible to the extent to which proper diagnosis is feasible in order to reduce tumor growth in lower extremity examination. The purpose of this study was to optimize the radiation dose in the long bone examination in standing position. Material and Methods: This experimental study was conducted to evaluate the radiation exposure dose to a phantom and estimate effective doses and organ-specific doses (i.e., testes and ovaries) among patients using PC-based Monte Carlo program.  Results: A phantom examination in the posterior-anterior (PA) configuration produced a radiation dose nine and three times smaller than those in the anterior-posterior (AP) and AP with shielding configurations, respectively. In a patient study (PA configuration), the testes, ovaries and effective doses were estimated at 15, 1.2, and 2 times smaller than those in the AP configuration, respectively. Conclusion: This study demonstrated that examinations in the PA configuration produce a smaller radiation dose than those in the AP configuration.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo radiography simulation for assessment of absorbed radiation dose in femur bone marrow during X-ray radiography for constant mAs and AEC techniques

Background: The purpose of this study was to find the accurate absorbed dose in the femur bone marrow during the X-ray radiography for constant mAs and AEC techniques. Materials and Methods: The DOSXYZnrc was used to simulate radiation doses in two human femurs during diagnostic radiography. EGSnrc phantoms produced from actual CT images of human femurs were modified by adding seven micrometre ...

متن کامل

Evaluation of Radiation Exposure Pattern and Radiation Absorbed Dose Resulting from Occupational Exposure of Anesthesiologists to Ionizing Radiation

Introduction: Little information is available concerning the radiation exposure of anesthesiologists, and no such data have previously been collected in Iran. This prospective study was performed to determine the amount of radiation exposure of anesthesiologists for the purpose of assessing whether or not dangerous levels of radiation exposures were being reached, and to identify factors that c...

متن کامل

Positioning long lines: contrast versus plain radiography.

AIM To assess the value of contrast versus plain radiography in determining radio-opaque long line tip position in neonates. METHODS In a prospective study, plain radiography was performed after insertion of radio-opaque long lines. If the line tip was not visible on the plain film, a second film with contrast was obtained in an attempt to visualise the tip. RESULTS Sixty eight lines were i...

متن کامل

Evaluation of the Entrance Surface Dose (ESD) and Radiation Dose to the Radiosensitive Organs in Pediatric Pelvic Radiography

Background Patients' dosimetry is crucial in order to enhance radiation protection optimization and to deliver low radiation dose to the patients in a radiological procedure. The aim of this study was to assess the entrance surface dose (ESD) and radiation dose to the radiosensitive organs in pediatric pelvic radiography. Materials and Methods The studied population included 98 pediatric patien...

متن کامل

Digital Tomosynthesis for PNS Evaluation: Comparisons of Patient Exposure and Image Quality with Plain Radiography

OBJECTIVE We investigated low dose digital tomosynthesis (DT) for the evaluation of the paranasal sinus (PNS), and compared its diagnostic accuracy with a PNS radiography series (XR). MATERIALS AND METHODS We enrolled 43 patients for whom XR, PNS DT, and OMU CT were performed. We measured effective doses (EDs) of XR, DT, and OMU CT using Monte Carlo simulation software. Two radiologists perfo...

متن کامل

Effective Dose Evaluation of Critical Organes in Digital Radiography Exames

Background and Aim: Due to the increasing number of radiographic tests, TLD dosimeters can be used to measure the effective dose of critical organs in various radiographic tests. In this research, the progression of analogue to digital radiology devices, which facilitates and accelerates the performance of radiographs, especially emergency patients, was investigated, and then the effective dose...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 16  شماره 5

صفحات  372- 376

تاریخ انتشار 2019-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023