Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter
نویسندگان
چکیده مقاله:
Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was used to investigate the dosimetric effect of GNP size in megavoltage (MV) photon beam radiotherapy.Material and Methods: GNPs with the size of 30nm, 50nm and 100nm in diameter were used. Transmission electron microscope (TEM) and dynamic light scattering (DLS) were applied to analyze the size of nanoparticles. The MAGICA polymer gel was synthesized and impregnated with different sizes of GNPs. The samples were irradiated with 6MV photon beam and 24 hours after irradiation, they were read using a Magnetic Resonance Imaging (MRI) scanner. Macroscopic Dose Enhancement Factor (DEF) was measured to compare the effect of GNP size. The MAGICA response of the 6MV x-ray beam was verified comparing Percentage Depth Dose (PDD) curve extracted from polymer gel dosimetry and Treatment Planning System (TPS).Results: MAGICA polymer gel dose response curve was linear in the range of 0 to 10 Gy. DEFs by adding 30nm, 50nm and 100nm GNPs were 1.1, 1.17 and 1.12, respectively. PDD curves of polymer gel dosimeter and treatment planning system were in good agreement.Conclusion: The results indicated a substantial increase in DEF uses a MV photon beam in combination with GNPs of different sizes and it was inconsistent with previous radiobiological studies. The maximum DEF was achieved for 50nm GNPs in comparison with 30nm and 100nm leading to the assumption of self-absorption effect by larger diameters. According to the outcomes of this work, MAGICA polymer gel can be recommended as a reliable dosimeter to investigate the dosimetric effect of GNP size and also a useful method to validate the current radiobiological and simulation studies.Â
منابع مشابه
Effect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter
Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date.Objective: The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material.Methods: In this work t...
متن کاملEffect of Gold Nanoparticle on Percentage Depth Dose Enhancement On Megavoltage Energy in MAGICA Polymer Gel Dosimeter
BACKGROUND Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. OBJECTIVE The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. METHODS In this wor...
متن کاملeffect of gold nanoparticle on percentage depth dose enhancement on megavoltage energy in magica polymer gel dosimeter
background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. objective: the aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. methods: in this work...
متن کاملDose enhancement effect of gold nanoparticles on MAGICA polymer gel in mega voltage radiation therapy
Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. Among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. Material and Methods: In this study...
متن کاملEffect of gold nanoparticles on dose enhancement of 6 Mv X-rayin MAGIC_f polymer gel dosimeter
Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise...
متن کاملdose enhancement effect of gold nanoparticles on magica polymer gel in mega voltage radiation therapy
background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like developed to date. among the special features of this type of dosimeters, is be doped with other elements or chemicals which made them appropriate for investigating of dose enhancement with contrast agents, by high atomic number. material and methods: in this study...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 9 شماره 1
صفحات -
تاریخ انتشار 2019-02-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023