Evaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA

نویسندگان

  • A Sinha Faculty of Physical Science, Shri Ramswaroop Memorial University, Lucknow
  • A Yadav Department of Radiodiagnosis, Uttar Pradesh Rural Institute of Medical Sciences & Research, Saifai- Etawah- 206130
  • B Dixit Faculty of Physical Sciences, Shri Ramswaroop Memorial University, Lucknow- 225003
  • H Patni Bhabha Atomic Research Center, Mumbai- 400085
  • N Painuly Department of Radiotherapy, King George Medical University, Lucknow-226003
  • N Singh Department of Radiotherapy, King George Medical University, Lucknow-226003
چکیده مقاله:

Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fraction values for monoenergetic electrons of energies 15, 50, 100, 500, 1000 and 4000 keV were evaluated for the Digimouse voxel phantom incorporated in Monte Carlo code FLUKA. The organ sources considered in this study were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal, eye and brain. The considered target organs were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal and brain. Eye and brain were considered as target organs only for eye and brain as source organs. From the latest report (International Commission on Radiological Protection ICRP) publication number 110, organ compositions and densities were adopted.Results: The electron specific absorbed fraction values for self-irradiation decreases with increasing electron energy. The electron specific absorbed fraction values for cross-irradiation are also found to be dependent on the electron energy and the geometries of source and target. Organ masses and electron specific absorbed fraction values are presented in tabular form. Conclusion: The results of this study will be useful in evaluating the absorbed dose to various organs of mice similar in size to the present study. 

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA

Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...

متن کامل

Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA

BACKGROUND Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs. OBJECTIVE SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV we...

متن کامل

estimation of photon specific absorbed fractions in digimouse voxel phantom using monte carlo simulation code fluka

background: most preclinical studies are carried out on mice. for internal dose  assessment of a mouse, specific absorbed fraction (saf) values play an important role.  in most studies, saf values are estimated using older standard human organ compositions  and values for limited source target pairs. objective: saf values for monoenergetic photons of energies 15, 50, 100, 500,  1000 and 4000 ke...

متن کامل

Specific Absorbed Fractions of Internal Photon and Electron Emitters in a Human Voxel-based Phantom: A Monte Carlo Study

The specific absorbed fraction (SAF) of energy is an essential element of internal dose assessment. Here reported a set of SAFs calculated for selected organs of a human voxel-based phantom. The Monte Carlo transport code GATE version 6.1 was used to simulate monoenergetic photons and electrons with energies ranging from 10 keV to 2 MeV. The particles were emitted from three source organs: kidn...

متن کامل

Evaluation of dose distribution of 12C ion beam in radiotherapy by FLUKA as a Monte Carlo simulation Code

Introduction: Nowadays, the use of heavy ion beams in cancer therapy have been developed worldwide.   Materials and Methods: It requires accurate understanding of the complex processes of ion interaction with matter, as it is the calculation the relative dose & range of these ions in matter. In the present study we used FLUKA as a numerical Monte Carlo simula...

متن کامل

Monte Carlo Simulation of Radiation effects in protection layers of logical cell of the digital gate in ‎the FPGA for electron and proton rays Using the FLUKA Code

In this paper, radiation effects in protection layers of logical cell of the digital gate in the FPGA for electron and proton rays was simulated Using the FLUKA Code. by using of the Monte Carlo simulation, the electron and proton transport into the logical cell of the digital gate in the FPGA will be studied. In this simulation, the maximum energy of the electrons and protons at the entrance o...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 2

صفحات  -

تاریخ انتشار 2019-04-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023