Evaluation of dose uniformity in total body irradiation (TBI) technique in parallel-opposed anterior/posterior geometry using Varian Clinac 2100C/D linear accelerator
نویسندگان
چکیده مقاله:
Background: Total body irradiation (TBI) is a technique that is commonly used as a part of the patient conditioning regimen before the bone marrow transplant (BMT). The purpose of this study is to introduce and implement a reasonable TBI technique on the human-like phantom in Imam Khomeini Hospital in Tehran. Methods: The present experimental study was conducted from October 2016 to November 2017 to implement the TBI technique at the Cancer Institute of Imam Khomeini Hospital in Tehran. For this purpose, percentage depth dose, and dose rate were measured in TBI condition (i.e. SSD=310 cm, field size=40×40 cm2, gantry angle=90°, and collimator angle 45°) in homogeneous phantom. Gafchromic EBT3 films were used to measure the absorbed dose in different areas of the human like phantom at the levels of head, neck, thyroid, lung, umbilicus, pelvic, thigh, knee and leg. Phantom irradiation was performed in parallel opposed anterior-posterior geometry using an 18MV photon beam produced by Varian 2100C/D. Cerrobend blocks were used for lung protection. After analyzing the exposed films with Image J software, the dose uniformity was calculated. Results: Dose distribution uniformity was acquired in the order of -1.01% to +11.82% relative to the prescribed dose at the umbilicus. The difference between the calculated and measured dose at the umbilicus level was -2.73%. The radiation absorbed dose to the lung with blocks was 127.53cGy in one fraction which resulted in 756.18cGy in six fractions. Conclusion: The implemented technique, obtained the acceptable ±10% dose uniformity in most of the body regions. The dosing accuracy was within the acceptable range. The lungs¢ dose was reduced to the desired level using lung shields. This technique is a simple and cost-effective method that does not require complicated dosimetric techniques. Regarding the obtained results, the proposed technique has the necessary conditions for implementation in Imam Khomeini hospital in Tehran.
منابع مشابه
Review of techniques for improving the uniformity of dose distribution in total body irradiation (TBI) with parallel – opposed anterior and posterior geometry
Total body irradiation (TBI) is a kind of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression before bone marrow transplantation. As recommended by AAPM dose distribution uniformity in TBI is very important and dose variation must be within ±10% of prescription dose. Patients treatment geometry for TBI techniques fall into two co...
متن کاملDiode calibration for dose determination in total body irradiation
Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calib...
متن کاملCraniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
Background: Craniospinal irradiation (CSI) of medulloblastoma poses technological challenges due to the involvement of large treatment volume. Commonly, the whole treatment length is covered with two different isocentric plans in which the junction is shifted after every five fractions to overcome the possibility of hot and cold spot.Objective: This study aims to evaluate dosimetrically and cli...
متن کاملDose Evaluation in the Movement Couch of the Total Body Irradiation Technique Using Semiconducting Diodes and Thermoluminescence Detectors
Aim: The present study is devoted to evaluate the dose at different points defined on the patient using semiconducting diodes and thermoluminescence detectors to excute verification of the dose at these relevant points calculated by means of movement couch and Beam Zones method of the Total Body Irradiation Technique. Material and Method: In this technique; 11 patients using 6 MV X-ray in the (...
متن کاملIntensity-modulated Total Body Irradiation (TBI) with TomoDirect™
BACKGROUND The new TomoDirect™ modality offers a non-rotational option with discrete beam angles. We have investigated this mode for TBI with the intention to test the feasibility and to establish it as a clinical routine method. Special foci were directed onto treatment planning, dosimetric accuracy and practical aspects. PATIENTS AND METHODS TBI plans were calculated with TomoDirect™ for a ...
متن کاملTotal Body Irradiation (TBI) using Helical Tomotherapy in children and young adults undergoing stem cell transplantation
BACKGROUND Establishing Total Body Irradiation (TBI) using Helical Tomotherapy (HT) to gain better control over dose distribution and homogeneity and to individually spare organs at risk. Because of their limited body length the technique seems especially eligible in juvenile patients. PATIENTS AND METHODS The cohort consisted of 10 patients, 6 female and 4 male, aged 4 - 22 y with acute lymp...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 78 شماره 7
صفحات 434- 441
تاریخ انتشار 2020-10
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023