Evaluation of cumulative kidney activity in pediatric nuclear scan of the bladder using conjugate view method and four different techniques for correcting background radiations

نویسندگان

  • Ali Ebrahimi Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
  • Masoud Moslehi Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
  • Mohammad Reza Salamat Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
چکیده مقاله:

Background: At present, in nuclear medicine to calculate the cumulative activity of various organs, different techniques are being used to correct the background radiations in the conjugate view method. Each of these techniques considers the effect and weight of background radiations to a different extent. These background radiations can cause errors in cumulative activity calculations. The purpose of this study was to evaluate and compare different techniques of correcting background radiations to each other in calculating kidney cumulative activity during the nuclear scan of the bladder in children. Methods: This study was Cross-sectional and performed for patients who were referred to Isfahan Shahid Chamran Hospital between December 2019 and June 2020. In this study using Foley, 1 mCi of TC-DTPA radio-pharmaceutical that was diluted with normal saline was injected into the patient's bladder, then images recorded by gamma cameras were extracted at 2, 5, 10, and 20 minutes, Finally with ROI drawing around kidney with having vesicoureteral reflux, Cumulative renal activity was calculated with four correcting background radiations techniques such as without correction of background radiation, conventional method, Buijs method, and Kojima method Eventually, the data was Eventually, the data was compared to each other to determine how much weight each of these techniques consider for background radiations. Results: Cumulative kidney activity after calculation with four correcting background radiations techniques such as without correction of background radiation, conventional method, Buijs method, and Kojima method were 14.970±4.776, 13.544±4.357, 13.885±4.451, 13.879±4.449 mCi.min. respectively After comparing the calculated cumulative activity without correcting the background radiations with the cumulative activity calculated by the three techniques of correcting the background radiations such as the conventional method, Buijs method, and Kojima method, the value (P<0.05) was obtained in all cases, which shows that elimination of background radiations is significantly meaningful in the calculations of cumulative activity in the conjugate method for nuclear exams Conclusion: after comparing correcting background radiations techniques to each other, it was determined that the conventional method technique considers the effect and weight of background radiations more than the two other techniques such as the Buijs method and Kojima method in cumulative activity calculations.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

estimation of organ activity using four different methods of background correction in conjugate view method

to make an accurate estimation of the uptake of radioactivity in an organ using the conjugate view method, corrections of physical factors, such as background activity, scatter, and attenuation are needed. the aim of this study was to evaluate the accuracy of four different methods for background correction in activity quantification of the heart in myocardial perfusion scans. the organ activit...

متن کامل

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

buckling of viscoelastic composite plates using the finite strip method

در سال های اخیر، تقاضای استفاده از تئوری خطی ویسکوالاستیسیته بیشتر شده است. با افزایش استفاده از کامپوزیت های پیشرفته در صنایع هوایی و همچنین استفاده روزافزون از مواد پلیمری، اهمیت روش های دقیق طراحی و تحلیل چنین ساختارهایی بیشتر شده است. این مواد جدید از خودشان رفتارهای مکانیکی ارائه می دهند که با تئوری های الاستیسیته و ویسکوزیته، نمی توان آن ها را توصیف کرد. این مواد، خواص ویسکوالاستیک دارند....

the use of appropriate madm model for ranking the vendors of mci equipments using fuzzy approach

abstract nowadays, the science of decision making has been paid to more attention due to the complexity of the problems of suppliers selection. as known, one of the efficient tools in economic and human resources development is the extension of communication networks in developing countries. so, the proper selection of suppliers of tc equipments is of concern very much. in this study, a ...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 79  شماره 7

صفحات  499- 506

تاریخ انتشار 2021-10

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023