Evaluating Response Modification Factors of Concentrically Braced and Special Moment Steel Frames in Duplex Buildings
نویسندگان
چکیده مقاله:
Response modification factor (R-factor) is one of the seismic design parameters to consider nonlinear performance of building structures during strong earthquake. Relying on this, many seismic design codes led to reduce earthquake loads imposed to the structure. The present paper tries to evaluate the R-factors of conventional concentric braced frames (CBFs) and special moment frames (MRFs) in duplex steel buildings with level difference in their floors. Since, the R-factor depends on ductility and over strength, the incremental nonlinear static analysis, push over analysis, has been performed on 4, 7 and 10 storey building models with three floor level differences and including CBFs and special MRFs systems in x and y directions of buildings respectively. The results showed that the R-factors for CBFs system in duplex buildings were higher than ones in conventional buildings without floor level differences while for MRFs system it was found that on 4 and 7 storey duplex buildings, the R-factors were decreased and with the increase in building height to 10 storey, they were increased compared to conventional models.
منابع مشابه
evaluating response modification factors of concentrically braced and special moment steel frames in duplex buildings
response modification factor (r-factor) is one of the seismic design parameters to consider nonlinear performance of building structures during strong earthquake. relying on this, many seismic design codes led to reduce earthquake loads imposed to the structure. the present paper tries to evaluate the r-factors of conventional concentric braced frames (cbfs) and special moment frames (mrfs) in ...
متن کاملNew expressions to estimate damping in direct displacement baseddesign for special concentrically-braced frames
Different expressions have been developed to determine damping of structures based on various hysteretic models and ductility levels. Since Slenderness ratio is an important parameter on the hysteretic behavior of special concentrically- braced frames (SCBF), in this paper new expressions for determination of damping of such frames are developed based on slenderness ratio and ductility. Two typ...
متن کاملConcentrically Braced Frames: European vs. North American Seismic Design Provisions
A critical review of seismic design provisions for concentrically braced frames (CBFs) in both European and North American (i.e. US and Canadian) codes is presented in this paper. Indeed, even though those codes are based on capacity design philosophy, different requirements and different approaches are used to guarantee the hierarchy of resistances between dissipative and non-dissipative eleme...
متن کاملEvaluating Equivalent Damping and Response Modification Factors of Frames Equipped by Pall Friction Dampers
A study on the evaluating equivalent damping and response modification factors of frames equipped by Pall Friction Dampers is presented. To do so, buildings with various stories were considered. Nonlinear and linear dynamic time history analysis has been performed to evaluate equivalent damping for Pall Friction Dampers. Ground motions with various frequency characteristics scaled with Iranian ...
متن کاملAssessing Seismic Performance of the Elliptic Braced Moment Resisting Frame through Pushover Method
The seismic performance of elliptic braced moment resisting frame (ELBRF) is assessed here and is found that the structural behavior is improved and is of free of architectural space. The demand for seismic performance of ELBRF is estimated through conventional pushover methods of 3, 5, 7, and 10-story ELBRF frames and they are compared with special moment resisting frames (SMRF) and X-Braced C...
متن کاملComparison of the Progressive Collapse Resistance of Seismically Designed Steel Shear Wall Frames And Special Steel Moment Frames
In this study, the progressive collapse potential of seismically designed steel plate shear wall (SPSW) systems is investigated using the alternate path method, and their performances are compared with those of the conventional special moment frame (SMF) systems. Nonlinear static and dynamic analyses are conducted to follow the progressive collapse of the structures, and their ability of absorb...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 5 شماره 1
صفحات 31- 38
تاریخ انتشار 2015-03-30
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023