Estimation of neutron and gamma dose in the MNSR research reactor

نویسندگان

چکیده مقاله:

In this study, the neutron and gamma doses in the dry channel and in the internal irradiation site of the Miniature Neutron Source research reactor (MNSR) has been calculated and measured. The MNSR reactor is a light water reactor with a maximum power of 30 kW and equipped with various irradiation facilities, including five irradiated sites, five irradiation sites and a dry channel. The internal irradiation sites have the closest gap to the core of the reactor, with the highest flux and doses available in these locations. Dose calculations have been performed using simulation of the reactor by MCNP computational code and dose measurement using TLD600 and TLD700 thermo-luminescence dosimeters. The experiments have been carried out at both the shutdown and operational status of reactor. In order to validate the computational code, the neutron flux in the internal irradiation site and at the end of the dry channel has been measured by foil activation method and validated by the calculation results. The results of the calculation and measurement of the neutron and gamma doses were in good agreement. The determination of neutron and gamma doses at these sites makes possible such experiments and researches that need to receive a precise amount of neutron and gamma doses.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of neutron radiography in the MNSR Low Power Research Reactor

Neutron radiography is an unique, advanced and useful non-destructive test method in various industries and researches. Nuclear reactors are powerful and stable neutron sources for the neutron radiography system. In this research, the MNSR research reactor has been used as a neutron source for a neutron radiography system, and its neutron beam parameters have been evaluated. Also, using the dir...

متن کامل

Calculation and evaluation of the vital head organs dose during Neutron Therapy in Tehran Research Reactor using Zubal phantom

In the recent years some studies has been done to consider the capability of Tehran Research Reactor for Boron neutron capture therapy (BNCT). The purpose of this study is to evaluate the sensitive organs dose during the treatment of patient with deep brain tumor by TRR. The calculation has been carried out using the Monte Carlo code MCNPX for ZUBAL head and neck phantom. The method was tested ...

متن کامل

Modeling the measurement of VVER-1000 reactor power by neutron and gamma radiation with MCNP code

The present study deals with a new method for measuring the power of a reactor. This method uses gamma and neutron radiation resulted from the entire reactor structure, without changing its structure (online). In terms of functionality, this method can measure the reactor power in real-time and report it instantly. In order to obtain the relationship between reactor power and gamma and neutron ...

متن کامل

Estimation of neutron effective dose from DD and DT neutron generators and the design of appropriate shield for standing user

Neutron Generators (NG) are used as a neutron source for different applications. During recent years, major efforts are underway to develop a high yield compact NG. In this way, radiation protection aspects need to be considered during the operation of these high yield NGs. In this paper the neutron effective dose of a NG operator has been calculated using MCNPX Monte Carlo code. The results sh...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 4

صفحات  53- 58

تاریخ انتشار 2020-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023