Energy window setting for optimum Tl-201 cardiac imaging [Persian]

نویسندگان

  • Ahmad Bitarafan Rajabi Department of Medical Physics, Tarbiat Modarres University, Tehran, Iran
  • Faraz Kalantari Department of Medical Physics, Tarbiat Modarres University, Tehran, Iran
  • Fereidoon Rastgoo Nuclear Medicine Department, Shahid Rajaie Heart Hospital, Iran University of Medical Sciences, Tehran, Iran
  • Hadi Malek Nuclear Medicine Department, Shahid Rajaie Heart Hospital, Iran University of Medical Sciences, Tehran, Iran
  • Hossein Rajabi Department of Medical Physics, Tarbiat Modarres University, Tehran, Iran
  • Kourosh Gorji Department of Medical Physics, Lorestan University of Medical Sciences, Khoramabad, Iran
  • Nahid Yaghoobi Nuclear Medicine Department, Shahid Rajaie Heart Hospital, Iran University of Medical Sciences, Tehran, Iran
  • Seyed Hasan Firoozabadi Nuclear Medicine Department, Shahid Rajaie Heart Hospital, Iran University of Medical Sciences, Tehran, Iran
چکیده مقاله:

  Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is very complicated and photons are emitted in a wide range of energies of 68-82 keV. It seems possible to achieve better primary to scattered radiation ratio and better image sensitivity simultaneously if the energy window setting is carefully selected. Methods: This investigation was performed in three steps: Monte Carlo simulation, phantom experiment and clinical study. In simulation step, the new 4D digital NCAT phantom was used to simulate the distribution of activity (201Tl) in patient torso organs. The same phantom was used to simulate the attenuation coefficient of different organs of the typical patient's body. Two small defects on different parts of left ventricle also were generated for further quantitative and qualitative analysis. The simulations were performed using the SimSET simulator to generate images of such patient. The emissions arising from Tl-201 decay were simulated in four steps using the energies and relative abundances. Energy spectra for primary and scatter photons were calculated. Changing the center and width of energy windows, optimum energy window characteristics were determined. In next step jaszczak phantom was prepared and used for SPECT imaging in different energy windows. In last step SPECT images of 7 patients who had angiographic data were acquired in different energy windows. All of these images were compared qualitatively by four nuclear medicine physicians independently. Results: The optimum energy window was determined as a wider asymmetric window (77keV30%) that its center is not placed on photo-peak of energy spectrum. This window increased the primary counts rate and PTSR considerably as compared with the conventional symmetric energy window (67keV%). In a comparison which performed between clinical images acquired in suggested 77-30% window with conventional 67-20% window, a considerable increase was found in myocardial to defect contrast (1.541±0.368) and myocardial to cavity contrast (1.171± 0.099). A negligible increase was also found in total counts of images using this window. Conclusion: We found that conventional symmetric energy window (67keV± 10%) couldn't be a suitable choice for thallium heart imaging; furthermore three energy windows, 73keV-30%, 75keV-30% and 77keV-30%, were determined as optimum window options. For further analysis the images from such windows were compared in each three steps of this investigation. In all steps conventional symmetric energy window (67keV-20%) was introduced as the worst case and the asymmetric 77keV-30% was determined as the most suitable.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

energy window setting for optimum tl-201 cardiac imaging [persian]

introduction: poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. scattered photons are the main cause of degrading the contrast and resolution in spect imaging that result in error in quantification. thallium decay is very complicated and photons ar...

متن کامل

Optimum energy window setting on Hg-201 x-rays photopeak for effective Tl-201 imaging.

For more effective Tl-201 imaging, the location and width of the energy window set on the Hg-201 x-rays photopeak was investigated using Monte Carlo simulation and phantom experiments. We calculated energy spectra and investigated the amount of primary and scattered photons within various energy windows set on the x-rays photopeak. The energy resolution (ER) at 71 keV (the peak of the x-rays ph...

متن کامل

Appropriate energy window width for gamma camera [Persian]

Introduction: Scatter radiation is one of the major sources of error in nuclear medicine data processing. Different methods of scatter correction have been introduced in order to improve the quality of data. However the best method is to avoid recording of scatter photons in acquisition. The only difference between scattered and non-scattered photons is the energy. Pulse height analyzer i...

متن کامل

Dose Nitroglycerine enhance detection of viable myocardium by Tl-201 SPECT? [Persian]

It is suggested that sublingual nitroglycerine can improve the ability of T1-201 for detection of viable myocardium. Methods and Results: In a randomized, double blind study, 50 patients who had fixed defects on stress-redistribution scan, were randomized into two groups. In group I, patients received 0.4-0.8 mg sublingual nitroglycerine, before T1-201 reinjection. In group II, reinjectio...

متن کامل

STANDARDIZATION OF Tl-201 RADIOACTIVE SOLUTION

The standardization of Tl, using the 4π(PC)-NaI(Tl) coincidence system, is presented. The disintegration rate was determined by the extrapolation technique, using two methods: electronic discrimination and external absorbers. A Monte Carlo simulation program, developed in our laboratory, which predicts the behavior of the extrapolation curve, was applied and the results were compared with exper...

متن کامل

Detection of denervated but viable myocardium in cardiac sarcoidosis with I-123 MIBG and Tl-201 SPECT imaging.

A 58-year-old man, who had biopsy-proven cardiac sarcoidosis, underwent TI-201 and I-123 MIBG cardiac scintigraphy. Although no perfusion defect was identified by Tl-201, mild heterogeneity of I-123 MIBG uptake was present in the myocardium. The denervated but viable myocardium was demonstrated in the heart with sarcoidosis. Cardiac sympathetic nerve function was impaired in cardiac sarcoidosis...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره 2

صفحات  15- 24

تاریخ انتشار 2007-10-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023