Electrochemical Determination of Mesalazine by Modified Graphite Paste Electrode with Poly (Benzoquinone) Chromium(III) Complex
نویسندگان
چکیده مقاله:
In this work, for the first time poly (benzoquinone) chromium (III) complex (PBQC) was synthesized with a one pot, one step, simple and fast method. This novel polymer was used for modification of graphite paste electrode for electrochemical determination of Mesalazine. Moreover, this novel modifier was characterized by Fourier transform infrared spectroscopy, Field emission scanning electron microscopy, Energy-dispersive X-ray spectroscopy, Electrochemical impedance spectroscopy and electrochemistry methods such as cyclic voltammetry and differential pulse voltammetry. Various parameters which affect the electroanalytical application of this modified electrode were optimized and under the optimum condition, the calibration curve was linear in a wide range from 2 to 600 µM with a detection limit (S/N=3) of 70 nM. The proposed modified electrode is a good candidate for the determination of Mesalazine with satisfactory results in comparison with the other literature. Moreover, the proposed modified electrode, GPE/PBQC, was successfully used for determination of Mesalazine in pharmaceutical tablets.
منابع مشابه
A New Electrochemical Sensor for Determination of Zolpidem by Carbon Paste Electrode Modified with SnS@SnO2NP
Zolpidem is a drug that is easily attached to the GABA receptors in the brain. This property makes it very effective for tranquilizing as well as hypnagogia. According to the advantages of electrochemical analysis like high selectivity, high sensitivity, low concentration of analyte, cost-effective, portable and easy-to-use setup, they gained high amount of attention among scientists for determ...
متن کاملElectrochemical Behavior of 2-Aminothiazole at Poly Glycine Modified Pencil Graphite Electrode
Electro analysis of 2-Aminothiazole (2-AT) by a low cost poly Glycine modified Pencil Graphite Electrode (poly Gly/PGE) was studied using of cyclic voltammetric (CV) and differential pulse voltammetric (DPV) techniques. The optimal experimental conditions to determine 2-AT was setup by the variation of the current with scan rate, concentration and pH. Electrochemical performance of the 2-AT at ...
متن کاملVoltammetric determination of cysteine at a carbon paste electrode modified with Cu(II)-salen complex
The electrochemical behavior of a modified carbon paste electrode (MCPE) with N,N′ethylenbis(salicylideneiminato)copper(II) complex ([Cu(II)-Salen]) was investigated as a newsensor for cystein. The Britton-Robinson buffer with pH 5, 10% modifier in electrode, potentialscanning rate of 20 mVs-1 and puls height of 50 mV were used as the optimum condition for thedetermination of cysteine using car...
متن کاملElectrochemical Behavior and Electrochemical Determination of Tiamulin Fumarate at an Ionic Liquid Modified Carbon Paste Electrode
The electrochemical behavior of tiamulin fumarate (TF) at ionic liquid N-Butylpyridinium hexafluorophosphate (BPPF6) modified carbon paste electrode (BPPF6/CPE) was investigated and further used for tiamulin fumarate sample determination. BPPF6/CPE showed an enhanced electrochemical response towards the electrochemical oxidation of TF. A well-defined and sensitive oxidation peak was observed at...
متن کاملElectrocatalytic Determination of Isoniazid by a Glassy Carbon Electrode Modified with Poly (Eriochrome Black T)
In this work poly eriochrome black T (EBT) was electrochemically synthesized on the glassy carbon electrode as electrode modifier. On the modified electrode, voltammetric behavior of isoniazid (INH) was investigated. The poly (EBT)-modified glassy carbon electrode has excellent electrocatalytic ability for the electrooxidation of isoniazid. This fact was appeared as a reduced overpotential of I...
متن کاملElectrochemical Behaviour of Tinidazole at 1,4-Benzoquinone Modified Carbon Paste Electrode and Its Direct Determination in Pharmaceutical Tablets and Urine by Differential Pulse Voltammetry
A simple and highly sensitive electrochemical method based on a 1,4-benzoquinone modified carbon paste electrode (1,4-BQMCPE) was described for the determination of tinidazole (TDZ). In Britton Robinson buffer solution, TDZ yields well-defined irreversible reduction peak at -0.344 V on a 1,4-BQMCPE. Compared with that on a bare CPE, the reduction peak of TDZ increased significantly on the modif...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 5 شماره 2
صفحات 343- 352
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023