Effects of End Sill and Step Slope on Stepped Spillway Energy Dissipation

نویسندگان

  • Abbas Mansoori Civil Engineering Department, Islamic Azad University, South Tehran Branch, Tehran, Iran
  • Abolfazl Shamsai Department of Technical and Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
  • Amirmasoud Hamedi Department of Technical and Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
  • Sepideh Amirahmadian Civil Engineering Department, Islamic Azad University, South Tehran Branch, Tehran, Iran
چکیده مقاله:

In this study, experimental procedure and laboratory works have been conducted to investigate the energy loss rate on stepped spillway, using inclined steps together with end sill. To have a more elucidated investigation inclined steps with different slopes (Horizontal , 7, 10, and 12 degrees with respect to the horizon) and end sill with different thicknesses (5 and 10 mm) and heights (6, 8, 10, and 15 mm) were used to determine the impact of these parameters on the relative energy loss. Results show that using inclined steps together with end sill has a considerable effect on the energy loss of both nappe (30 liter/sec) and skimming (90 liter/sec) flows; however, energy dissipation in nappe flows is greater than that in skimming flows. Energy loss resulted from end sills with smaller thicknesses is higher than that of end sills with greater thicknesses. Comparison of the results of the current survey with similar studies reveals that the approach used in the current investigation is more efficient than previous ones.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Slope and the Number of Steps on Energy Dissipation in Stepped Spillway Using Numerical Model

Recently the stepped spillways have been used as an appropriate solution for energy dissipation. In the present study, Siahbisheh dam spillway is simulated by using Computational Fluid Dynamic (CFD), in which the Mixture method and Reynolds Stresses Model (RSM) turbulence model is used. In the first modeling series the over all steppes slope is constant. The number of the steps is increased to ...

متن کامل

influence of slope and the number of steps on energy dissipation in stepped spillway using numerical model

recently the stepped spillways have been used as an appropriate solution for energy dissipation. in the present study, siahbisheh dam spillway is simulated by using computational fluid dynamic (cfd), in which the mixture method and reynolds stresses model (rsm) turbulence model is used. in the first modeling series the over all steppes slope is constant. the number of the steps is increased to ...

متن کامل

Stepped Spillway Performance: Study of the Pressure and Turbulent Kinetic Energy versus Discharge and Slope

In the present study, flow over flat and pooled stepped spillways was simulated three dimensionally. The VOF method and k- ε (RNG) turbulent model was used to simulate the flow over the stepped spillway. The results indicated that the numerical model was acceptably capable of simulating the flow over the pooled and flat stepped spillways for different discharges. Following that, the effect of d...

متن کامل

Energy Dissipation down a Stepped Spillway with Non- Uniform Step Heights

While most stepped spillway design guidelines were developed for uniform step heights, a nonuniform stepped design might be a practical alternative in some cases. A physical study was conducted in a moderate slope stepped chute (1V:2H) and five stepped configurations were tested for 0.7 < dc/h < 1.9. Detailed air-water flow measurements were performed for each configuration and the results were...

متن کامل

Effects of Step Pool Porosity upon Flow Aeration and Energy Dissipation on Pooled Stepped Spillways

The hydraulics of stepped spillways with flat steps has been studied for the last three decades, including for embankment dam slopes, but studies of alternative stepped designs are limited. In this study, a pooled stepped spillway was investigated in a relatively large-size facility, and three different pool wall porosities were tested. The flow patterns, the macroand microscopic air-water flow...

متن کامل

Energy Dissipation and Residual Energy on Embankment Dam Stepped Spillways

Stepped spillways are designed to increase the rate of energy dissipation on the chute and to reduce the size of the downstream energy dissipator. It is essential to predict accurately the turbulent dissipation above the steps for large discharges per unit width corresponding to the skimming flow regime. New measurements were conducted in a large facility with a channel slope of 21.8o and a ste...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 6  شماره 1

صفحات  1- 15

تاریخ انتشار 2014-11-10

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023