Effective Source-Surface Distance in Various Field Sizes and Electron Beam Energies and its Effect on Cutout Factor in a Elekta Precise Linear Accelerator

نویسندگان

  • Akbar Aliasgharzadeh Department of Medical Physics, School of Paramedical Sciences, Kashan University of Medical Sciences, Kashan, Iran
  • Fateme Fallahi Department of Medical Physics, School of Paramedical Sciences, Kashan University of Medical Sciences, Kashan, Iran
  • Fatemeh Seif Department of Medical Physics and Rariotherapy, Arak University of Medical Sciences and Khansari Hospital, Arak, Iran
  • Fatholah Mohaghegh Department of Medical Physics and Rariotherapy, Arak University of Medical Sciences and Khansari Hospital, Arak, Iran
  • Mohamad Reza Bayatiani Department of Medical Physics and Rariotherapy, Arak University of Medical Sciences and Khansari Hospital, Arak, Iran
چکیده مقاله:

Introduction: In electron beam treatment, because of the non-point electron beam source, inverse-square law cannot be applied for dosimetry in different treatment intervals. Therefore, providing source-surface distance (SSD) charts in all clinics is of paramount importance. This study aimed to determine the effective SSD for various electron beam energies and field sizes and to evaluate its effect on cutout factor in a linear accelerator.   Materials and Methods: We used Elekta Precise linear accelerator in Ayatollah Khansari Hospital, Arak, Iran, for various energy levels (10, 15, and 18 MeV). The measurement environment was MP3-M water phantom (PTW Co., Canada), and diode detector was utilized for dosimetry. The effective SSD and cutout factor was estimated for 100, 105, 110, 115, and 120 cm SSDs and 1.5×1.5 and 20×20 cm2 square fields.   Results: The effective SSD in the 1.5×1.5 to 20×20 cm2 fields altered from 29.95 to 93.95 cm, 50.40 to 96.50 cm, and 63.51 to 95.32 cm for different energy levels of 10 MeV, 15 MeV, and 18 MeV, respectively. The cutout factor increased along with the field size, but decreased by extending the SSD. These alterations were more significant for the energy level of 10 MeV.   Conclusion: Since the effective SSD is dependent on energy level and field size, it is recommended to independently compute the effective SSD considering these variables. Furthermore, for designing accurate therapies, cutout factor variations should be considered for small-sized fields, especially at low energy levels.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy

Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...

متن کامل

The Effect of Field Size and Distance from the Field Center on Neutron Contamination in Medical Linear Accelerator

Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...

متن کامل

The Effect of Field Size and Distance from the Field Center on Neutron Contamination in Medical Linear Accelerator

Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...

متن کامل

effect of bataine and sulphate supplement on wool and milk characteristics and lambs performance in naine ewes

تعداد 20 رأس میش نژاد نائینی 6+-24 ماهه، با میانگین وزن 2/3-+40 کیلوگرم، همراه با 20 رأس بره های آنها در قالب طرح کاملا تصادفی اثر بتائین و مکمل سولفات بر خصوصیات شیر و پشم و عملکرد بره ها بررسی شد. میش ها بطور تصادفی در چهار تیمار قرار گرفتند. تیمارها عبارت بودند از: 1-گروه شاهد 2-بتائین (05/0 درصد ماده خشک) 3-سولفات (24/0 سولفور درصد ماده خشک 4-بتائین هرماه با سولفات. جیره غذائی طبق nrc با مح...

15 صفحه اول

Design and dosimetry characteristics of a commercial applicator system for intra‐operative electron beam therapy utilizing ELEKTA Precise accelerator

The design concept and dosimetric characteristics of a new applicator system for intraoperative radiation therapy (IORT) are presented in this work. A new hard-docking commercial system includes polymethylmethacrylate (PMMA) applicators with different diameters and applicator end angles and a set of secondary lead collimators. A telescopic device allows changing of source-to-surface distance (S...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  371- 371

تاریخ انتشار 2018-12-01