Effective Source-Surface Distance in Various Field Sizes and Electron Beam Energies and its Effect on Cutout Factor in a Elekta Precise Linear Accelerator
نویسندگان
چکیده مقاله:
Introduction: In electron beam treatment, because of the non-point electron beam source, inverse-square law cannot be applied for dosimetry in different treatment intervals. Therefore, providing source-surface distance (SSD) charts in all clinics is of paramount importance. This study aimed to determine the effective SSD for various electron beam energies and field sizes and to evaluate its effect on cutout factor in a linear accelerator. Materials and Methods: We used Elekta Precise linear accelerator in Ayatollah Khansari Hospital, Arak, Iran, for various energy levels (10, 15, and 18 MeV). The measurement environment was MP3-M water phantom (PTW Co., Canada), and diode detector was utilized for dosimetry. The effective SSD and cutout factor was estimated for 100, 105, 110, 115, and 120 cm SSDs and 1.5×1.5 and 20×20 cm2 square fields. Results: The effective SSD in the 1.5×1.5 to 20×20 cm2 fields altered from 29.95 to 93.95 cm, 50.40 to 96.50 cm, and 63.51 to 95.32 cm for different energy levels of 10 MeV, 15 MeV, and 18 MeV, respectively. The cutout factor increased along with the field size, but decreased by extending the SSD. These alterations were more significant for the energy level of 10 MeV. Conclusion: Since the effective SSD is dependent on energy level and field size, it is recommended to independently compute the effective SSD considering these variables. Furthermore, for designing accurate therapies, cutout factor variations should be considered for small-sized fields, especially at low energy levels.
منابع مشابه
Monte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy
Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...
متن کاملThe Effect of Field Size and Distance from the Field Center on Neutron Contamination in Medical Linear Accelerator
Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...
متن کاملThe Effect of Field Size and Distance from the Field Center on Neutron Contamination in Medical Linear Accelerator
Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...
متن کاملon the effect of linear & non-linear texts on students comprehension and recalling
چکیده ندارد.
15 صفحه اولeffect of bataine and sulphate supplement on wool and milk characteristics and lambs performance in naine ewes
تعداد 20 رأس میش نژاد نائینی 6+-24 ماهه، با میانگین وزن 2/3-+40 کیلوگرم، همراه با 20 رأس بره های آنها در قالب طرح کاملا تصادفی اثر بتائین و مکمل سولفات بر خصوصیات شیر و پشم و عملکرد بره ها بررسی شد. میش ها بطور تصادفی در چهار تیمار قرار گرفتند. تیمارها عبارت بودند از: 1-گروه شاهد 2-بتائین (05/0 درصد ماده خشک) 3-سولفات (24/0 سولفور درصد ماده خشک 4-بتائین هرماه با سولفات. جیره غذائی طبق nrc با مح...
15 صفحه اولDesign and dosimetry characteristics of a commercial applicator system for intra‐operative electron beam therapy utilizing ELEKTA Precise accelerator
The design concept and dosimetric characteristics of a new applicator system for intraoperative radiation therapy (IORT) are presented in this work. A new hard-docking commercial system includes polymethylmethacrylate (PMMA) applicators with different diameters and applicator end angles and a set of secondary lead collimators. A telescopic device allows changing of source-to-surface distance (S...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 371- 371
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023