Effect of Using Evaporative Condenser Instead of Air Condenser in Window-air Conditioners
نویسنده
چکیده مقاله:
In this paper, the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby preventing the reduction of cooling capacity and increasing power consumption of window-air-conditioners during very hot seasons. Two designs were developed for evaporative condensers. In the direct injection design, water is injected on the condenser coil directly while in the media pad design, water is injected on the media pad installed before the condenser. Thermodynamic properties of the systems after modification were measured and compared with the ordinary situation. Analysis of the results show that using these methods, the coefficient of performance increases by about 25% and power consumption decreases by about 13%. It is also anticipated that further modifications in these designs may yield better results
منابع مشابه
Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملEvaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملEffect of Condenser Air Flow on the Performance of Split Air Conditioner
Split air conditioning units are usually used for small and medium scale residential buildings. Therefore, more energy efficiency and lower cost are needed along with reliable control for the air conditioning units. An experimental investigation has been carried out to study the performance of a direct expansion air conditioning (A/C) unit having a variable speed condenser fan. The modulation o...
متن کاملR-410A Air Conditioning System With Microchannel Condenser
This paper presents experimental results from a prototype of a microchannel heat exchanger used in a residential air-conditioning system as an air-cooled condenser. The main objectives were to analyze effects of the microchannel condenser on system performance. The commercially available system that utilizes a condenser with a round tube and plate fins was experimentally evaluated first, then t...
متن کاملAssessment of Environmentally Friendly Refrigerants for Window Air Conditioners
This paper presents technical assessment of environmentally friendly refrigerants as alternatives to R410A for window air conditioners. The alternative refrigerants that are studied for its replacement include R32, R600a, R290, R1234yf, R1234ze and a mixture of R32 (90% molar concentration) and R125 (10% molar concentration). Baseline experiments were performed on a window unit charged with R41...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 22 شماره 2
صفحات 149- 159
تاریخ انتشار 2004-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023