Effect of Echo Time on the Maximum Relationship between Contrast Agent Concentration and Signal Intensity Using FLAIR Sequence
نویسندگان
چکیده مقاله:
Introduction Contrast-enhanced fluid-attenuated inversion recovery (FLAIR) is one of the MRI sequences that can be used for detection and evaluation of pathological changes in the brain. In this work, we have studied the effect of different echo times (TE) on the maximum relationship between signal intensity and concentration of the contrast agent using the FLAIR sequence. Materials and Methods For assessment of the relationship between signal intensity (SI) and concentration, a water-filled phantom containing vials of different concentrations of Gd-DTPA (0 to 19.77 mmol/L) was used. The mean SI was obtained in the region of interest when T1-weighted images were implemnted. The SI was corrected for coil non-uniformity. Results This study showed that an increase in TE is associated with a decrease in the maximum relationship between SI and concentration. Conclusion TE is an important parameter when the SI is measured in clinical FLAIR studies. The concentration leading to a maximum SI depends on this parameter, with the relevant concentration range decreasing at high TE.
منابع مشابه
effect of echo time on the maximum relationship between contrast agent concentration and signal intensity using flair sequence
introduction contrast-enhanced fluid-attenuated inversion recovery (flair) is one of the mri sequences that can be used for detection and evaluation of pathological changes in the brain. in this work, we have studied the effect of different echo times (te) on the maximum relationship between signal intensity and concentration of the contrast agent using the flair sequence. materials and methods...
متن کاملThe effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence
Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...
متن کاملon the relationship between using discourse markers and the quality of expository and argumentative academic writing of iranian english majors
the aim of the present study was to investigate the frequency and the type of discourse markers used in the argumentative and expository writings of iranian efl learners and the differences between these text features in the two essay genres. the study also aimed at examining the influence of the use of discourse markers on the participants’ writing quality. to this end the discourse markers us...
15 صفحه اولcomparison of maximum signal intensity of contrast agent on t1-weighted images using spin echo, fast spin echo and inversion recovery sequences
conclusion using standard imaging parameters, each mri sequence reaches its maximum si in a specific contrast concentration, which is highest in se and least in ir in a comparison between se, fse and ir sequences. results this study shows that maximum si will appear at different ranges in different sequences. the maximum si can be seen at concentrations of 5.95, 4.96 and 3.98mmol/l for se, fse ...
متن کاملon the relationship between the knowledge of collocations and writing proficiency
بررسی رابطه دانش همنشینی لغات و مهارت نوشتاری در زبان انگلیسی چکیده این پژوهش درصدد آن است تا سه مسئله زیر را مورد بررسی قرار دهد: الف) وجود یا عدم وجود رابطه بین دانش زبان آموزان در حوزه همنشینی لغات با یکدیگر و دانش آنها در مهارت نوشتاری زبان انگلیسی؛ ب) یافتن پاسخی به این سوال که آیا تمامی انواع همنشینی های لغوی زبان انگلیسی به یک میزان برای زبان آموزان دشوارند یا خیر؛ پ) مقایسه زبان آمو...
15 صفحه اولcomparison of maximum signal intensity of magnevist contrast agent in modified t1 weighted spin echo, t1 weighted fast spin echo and t1 weighted gradient echo sequences
background: nowadays mri examinations have been widely used in clinical applications for many diagnoses. the use of contrast agent in mri improves lesion detection and characterization and causes more accurate diagnosis. objectives: the aim of this study was comparing to optimal dose of magnevist contrast agent in modified t1w se (spin echo), t1w fse (fast spin echo) and t1w gre (gradient ech...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 10 شماره 1
صفحات 59- 67
تاریخ انتشار 2013-03-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023