Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value

نویسندگان

  • A Pirmoazen Postgraduate Student, Prosthodontics Dept, Faculty of Dentistry, Tehran Medical Sciences,
  • AR Banifatemeh Postgraduate Student, Prosthodontics Dept, Faculty of Dentistry, Tehran Medical Sciences,
  • E Hashemi Postgraduate Student, Prosthodontics Dept, Faculty of Dentistry, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
  • E Jalalian Associate Professor, Prosthodontics Dept, Faculty of Dentistry, Tehran Medical Sciences,
  • M Shariati Postgraduate Student, Prosthodontics Dept, Faculty of Dentistry, Tehran Medical Sciences,
  • S Alizadeh Prosthodontics
  • SH Naser Mostufi Assistant professor, Prosthodontics Dept, Faculty of Dentistry, Tehran Medical Sciences,
چکیده مقاله:

Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torque value (RTV). Materials and Methods: A total of 24 abutments and fixtures were evaluated in this in-vitro experimental study. Two abutments with internal and external connections were tightened to fixtures using a digital torque-meter according to the manufacturer's instructions. Half of the samples were subjected to cyclic loading with a 100-N mechanical load at a 1-Hz frequency (500,000 cycles) applied at 23±1°C with 50±5% humidity. Next, the RTV was measured for each abutment. Two-way analysis of variance (ANOVA) was used to assess the effect of the abutment system and cyclic loading on RTV.  Results: The highest RTV belonged to the internal connection abutment without cyclic loading (22 Newton-centimeter (Ncm)), while the lowest RTV was noted with the external connection abutment subjected to cyclic loading (14 Ncm; P<0.01). There was no statistically significant interaction effect between the two variables (the abutment system and cyclic loading; P=0.839). The RTV in the internal hexagon abutments was significantly higher than that in the external hexagon abutment system (P<0.001). Cyclic loading significantly reduced the RTVs in both abutments (P<0.001).   Conclusion: According to the results, internal connection abutments experience less screw loosening.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants.

PURPOSE The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants. MATERIALS AND METHODS Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of thread...

متن کامل

Comparison of the Effect of Two Different Abutment Diameters on Detorque Value Using Cyclic Loading and Thermocycling

Background and Aim: Screw loosening is a common problem with both screw-retained and cemented implant restorations. It is assumed that the abutment diameter affects detorque value and screw loosening. We aimed to determine the effect of two different abutment diameters on detorque value using cyclic loading and thermocycling. Materials and Methods: This in-vitro experimental study was conducte...

متن کامل

Effect of cyclic loading and retightening on reverse torque value in external and internal implants

PURPOSE The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. MATERIALS AND METHODS Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protoco...

متن کامل

Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

PURPOSE The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A ...

متن کامل

effect of seed priming and irrigation regimes on yield,yield components and quality of safflowers cultivars

این مطالعه در سال 1386-87 در آزمایشگاه و مزرعه پژوهشی دانشگاه صنعتی اصفهان به منظور تعیین مناسب ترین تیمار بذری و ارزیابی اثر پرایمینگ بر روی سه رقم گلرنگ تحت سه رژیم آبیاری انجام گرفت. برخی از مطالعات اثرات سودمند پرایمینگ بذر را بر روی گیاهان مختلف بررسی کرده اند اما در حال حاضر اطلاعات کمی در مورد خصوصیات مربوط به جوانه زنی، مراحل نموی، عملکرد و خصوصیات کمی و کیفی بذور تیمار شده ژنوتیپ های م...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 4  شماره 1

صفحات  36- 40

تاریخ انتشار 2019-03

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023