EEG Artifact Removal System for Depression Using a Hybrid Denoising Approach

نویسندگان

  • Chamandeep Kaur Department of Electronics and Communication Engineering, Panjab University Chandigarh, India.
  • Preeti Singh Department of Electronics and Communication Engineering, Panjab University Chandigarh, India.
  • Sukhtej Sahni Department of Psychiatry, Cheema Medical Complex, Mohali, India.
چکیده مقاله:

Introduction: Clinicians use several computer-aided diagnostic systems for depression to authorize their diagnosis. An electroencephalogram  (EEG) may be used as an objective tool for early diagnosis of depression and controlling it from reaching a severe and permanent state. However, artifact contamination reduces the accuracy in EEG signal processing systems. Methods: This work proposes a novel denoising method based on empirical mode decomposition (EMD) with detrended fluctuation analysis (DFA) and wavelet packet transform. At first, real EEG recordings corresponding to depressed patients are decomposed into various mode functions by applying EMD. Then, DFA is used as the mode selection criteria. Further wavelet packets decomposition (WPD) evaluation is used to extract the cleaner signals. Results: Simulations were carried out on real EEG databases for depression to demonstrate the effectiveness of the proposed techniques. To conclude the efficacy of the proposed technique, we identified signal-to-noise ratio (SNR) and mean absolute error  (MAE). The results show improved SNR and lower values of MAE for the combined EMD-DFA-WPD technique. Also, random forest and SVM (Support Vector Machine)-based classification showed improved accuracy of 98.51% and 98.10% for the proposed denoising technique, respectively. Whereas the accuracy of the EMD-DFA is 98.01% and 95.81% and EMD combined with DWT technique is 98.0% and 97.21% for the EMD- DFA technique for RF and SVM, respectively, as compared to the proposed method. Also, the classification performance for both classifiers was compared with and without denoising to highlight the effectiveness of the proposed technique. Conclusion: Our proposed denoising system results in a better classification of depressed and healthy individuals. These results can be further analyzed using other approaches to solve the mode mixing problem of the EMD approach.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact Removal from EEG Signals

Electroencephalographic (EEG) recordings are often contaminated with several artifacts.Powerline interference and baseline noise is always present in EEG response of every patient. A number of strategies are available to deal with noise effectively both at the time of EEG recording as well as during preprocessing of recorded data. The aim of the paper is to give an overview of the most common s...

متن کامل

Ocular Artifact Removal from EEG Using Stationary Wavelet Enhanced ICA

To analyze EEG accurately, it is necessary to remove artifacts from EEG, which gets coupled with signal at the time of recording and can’t be eliminated at preprocessing stage. Ocular artifact is most obvious artifact in EEG. In this paper, a new method using Stationary Wavelet Enhanced Independent Component Analysis with a novel thresholding, is proposed for ocular artifact removal from EEG. P...

متن کامل

Artifact removal from EEG signals using adaptive filters in cascade

Artifacts in EEG (electroencephalogram) records are caused by various factors, like line interference, EOG (electro-oculogram) and ECG (electrocardiogram). These noise sources increase the difficulty in analyzing the EEG and to obtaining clinical information. For this reason, it is necessary to design specific filters to decrease such artifacts in EEG records. In this paper, a cascade of three ...

متن کامل

Removal of EEG noise and artifact using blind source separation.

A study was performed to investigate and compare the relative performance of blind signal separation (BSS) algorithms at separating common types of contamination from EEG. The study develops a novel framework for investigating and comparing the relative performance of BSS algorithms that incorporates a realistic EEG simulation with a known mixture of known signals and an objective performance m...

متن کامل

Artifact Removal from Eeg Recordings – an Overview

Electrical impulses generated by nerve firings in the brain diffuse through the head and can be measured by electrodes placed on the scalp, is known as electroencephalogram (EEG) and was first measured in humans by Hans Berger in 1929. The EEG gives a coarse view of neural activity and has been used to noninvasively study cognitive processes and the physiology of the brain. The analysis of EEG ...

متن کامل

Co-recording of EEG and fMRI data: EEG artifact removal

The electroencephalogram (EEG) is a standard technique to record and study the brain activity with a high temporal resolution (ms). BOLD fMRI (Blood Oxygenation Level Dependent functional Magnetic Resonance Imaging) is a non-invasive imaging method that allows the localization of activated brain regions with a high spatial resolution (mm). The co-recording of these two complementary modalities ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 12  شماره 3

صفحات  0- 0

تاریخ انتشار 2021-06

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com