Dosimetric outcomes of the breast field-in-field (FIF) radiotherapy technique in patients with mastectomy and lumpectomy surgeries

نویسندگان

  • B. Ghadimi Department of Medical physics and Imaging, Urmia University of Medical Sciences, Urmia, Iran
  • K. Mostafanezhad Omid Research and Treatment Center, Urmia, Iran
  • L. Karimkhani Omid Research and Treatment Center, Urmia, Iran
  • N. Jabbari Solid Tumor Research Center, Department of Medical physics and Imaging, Urmia University of Medical Sciences, Urmia, Iran
چکیده مقاله:

Background: Field-in-field (FIF) technique for treatment of breast cancer has become a widely performed method over the recent years. However, there was no study in the application of FIF technique in patients with breast cancer undergoing mastectomy and lumpectomy. This study is an attempt to compare dosimetric outcomes after applying the FIF technique in these patients. Materials and Methods: Twenty-four&nbsp;patients with right and left breast cancer participated in this study. The FIF planning technique was carried out for patients undergoing mastectomy and lumpectomy using the TiGRT treatment planning system (TPS). For the comparison purpose, we used two main indices, i.e. dose homogeneity index (HI) and conformity index (CI), the number of subfields, as well as mean, maximum, and minimum doses, doses received by 2% (D2) and 98% (D98) of the target volume, volumes received greater than 107% (V>107%) and less than 95% (V<95%) of the prescribed dose, doses to organs at risk (OARs), and total monitor units (MUs). Results: The results indicated that CI and HI are better in patients with right and left breast lumpectomy surgery (p<0.038 and p<0.047) relative to mastectomy patients (p<0.037 and p<0.029), respectively. Other parameters mentioned in Materials and Methods did not show any significant difference between the two groups of patients (p>0.05). Conclusion: The use of alternative subfields resulted in better dose distribution in target volume with the increase in breast volume. Moreover, to disappear the hot spot areas in isodose curves, it is essential to elevate the number of subfields. &nbsp;

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

Dosimetric comparison of conventional and field-in-field techniques in early stage breast cancer radiotherapy

Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (F...

متن کامل

dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

background: we aimed to compare field-in-field technique (fif) with conformal tangential field radiotherapy (crt) in terms of dosimetric benefits for early stage breast cancer radiotherapy. materials and methods: twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. for each patient, two different treatment plans were created for...

متن کامل

Field-In-Field Plan Versus Tangential Wedged Beam Plan in Chest Wall Radiotherapy of Post-Mastectomy Patients: Treatment Planning Study

Introduction: In this study, dose distribution of the chest wall in post-mastectomy breast cancer patients was evaluated and compared in the tangential wedged beam (TWB) and field-in-field (FIF) plans. Materials and Methods: Thirty-six patients with left-sided breast cancer were enrolled in this study. The FIF and TWB plans were generated for each patient to compare dosimetric parameters of th...

متن کامل

the study of aaag repeat polymorphism in promoter of errg gene and its association with the risk of breast cancer in isfahan region

چکیده: سرطان پستان دومین عامل مرگ مرتبط با سرطان در خانم ها است. از آنجا که سرطان پستان یک تومور وابسته به هورمون است، می تواند توسط وضعیت هورمون های استروئیدی شامل استروژن و پروژسترون تنظیم شود. استروژن نقش مهمی در توسعه و پیشرفت سرطان پستان ایفا می کند و تاثیر خود را روی بیان ژن های هدف از طریق گیرنده های استروژن اعمال می کند. اما گروه دیگری از گیرنده های هسته ای به نام گیرنده های مرتبط به ا...

15 صفحه اول

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

*Corresponding author: Dr. Guler Yavas, Selcuk University, Faculty of Medicine Department of Radiation Oncology, Konya, Turkey. Fax: +90 332 241 60 65 E-mail: [email protected] Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 16  شماره None

صفحات  25- 32

تاریخ انتشار 2018-01