Dose GRID increase the unwanted photoneutron dose to the patients in GRID therapy?

نویسندگان

  • Amir Hossein Karimi Department of Medical physics, Jundishapur University of Medical Sciences, Ahvaz, Iran Student Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
  • Nahid Chegeni Department of Medical physics, Jundishapur University of Medical Sciences, Ahvaz, Iran
چکیده مقاله:

Introduction: GRID therapy is a treatment modality in which a high dose of radiation in a single fraction is given to the tumor. This technique previously was used to treat bulky tumors with orthovoltage beams. Recently, studies have been conducted to suggest that GRID therapy with megavoltage photons can be useful in palliative treatments. On the other hand, there has always been concern about the unwanted production of photoneutrons by LINAC head in treating with energies above 10 MeV. This problem is more worrying in modern radiotherapy techniques in which more monitor units are used, such as Intensity Modulated Radiotherapy (IMRT) and GRID therapy. So far, the effect of the GRID on photoneutron contamination has not been completely studied. While in terms of radiation protection, it is important to evaluate the GRID effect on photoneutron dose to the patients. In addition, one of the limitations of neutron dosimeters is that even with the most precise tools, one cannot achieve uncertainty less than 10% in measurements, while by Monte Carlo (MC) simulations, these limitations can be removed very much and a more accurate estimate of neutron dose can be provided. Materials and Methods: In this study, using the Monte Carlo code MCNPX, the main components of the Varian Clinac 2100 C/D were simulated. For 4×4, 10×10, and 20×20 cm2 field sizes, the Percentage Depth Dose (PDD) and profile curves were calculated and benchmarked with the measured data. After the model tuning, the neutron source strength of the LINAC (Q), the distributions of ambient dose equivalent (H*(10)) of neutrons were calculated on the treatment table for 10×10 cm2 field size, in both cases: with/without a typical GRID. Results: Our results indicate that, the GRID increases the neutron source strength by only 0.3% and also, one can see that the GRID reduces the ambient dose equivalent of neutrons at the isocenter (IC) 48.9%. In addition the average reduction in the ambient dose equivalent of neutrons is 38.5% at the intervals of less than 30 cm from the IC. Conclusion: It was found that in GRID therapy technique compared to conventional radiotherapy, the neutron dose on the treatment table is dramatically reduced. Therefore; there will be no concern about the increase of unwanted neutron dose in GRID therapy.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image Quality and Entrance Surface Dose Evaluation of Lateral Cervical Spine: A Study Using Grid and Non-Grid Techniques

Introduction: The purpose of this study is to investigate the effects of grid and non-grid techniques in the lateral cervical spine radiography on image quality and entrance surface dose (ESD). Although image quality and radiation doses have been studied by researchers, there is still a dearth of information on image quality and patient dose with different techniques. Material and Methods: The...

متن کامل

Statistical Study to Find the Optimal Dose of the First Phase in Leukemia Patients

Abstract. In this paper, a structured framework for determining the optimal dose of the first phase in leukemia patients is presented. And here we describe and discuss the key parameters that are needed to set up and run a CRM trial. These are: number of doses; maximum tolerable dose; Target Toxicity Level Dose-toxicity model; Dose-toxicity skeleton; Sample size and cohort size and Stopping ru...

متن کامل

Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology.Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the ab...

متن کامل

Evaluation of dosimetric characteristics of a grid block fabricated for Mega-voltage grid therapy purposes

Background: In conventional radiation therapy, regarding normal tissue tolerance, the treatment of bulk tumors is one of the remaining challenges. Grid Radiation Therapy (GRT) is a technique to deliver high doses, approximately 15 – 20 Gy per fraction, to several small volumes located in a large radiation field. This can be performed using a grid block. The current work has concentrate...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  106- 106

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023