Distal Femoral Valgus Cut Errors in Total Knee Replacement
نویسندگان
چکیده مقاله:
The causes of malalignment in total knee arthroplasty can be categorized into three different groups; 1) Errors in bone cuts 2) Errors in implant fixations, and 3) The method of setting down the cutting guides (1). We would like to announce that more several distal femoral valgus cut errors may occur during total knee replacement.
منابع مشابه
DIFFERENT REFERENCES FOR VALGUS CUT ANGLE IN TOTAL KNEE ARTHROPLASTY
This was Presented in 5th International congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
متن کاملDifferent References for Valgus Cut Angle in Total Knee Arthroplasty
Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...
متن کاملVarus distal femoral osteotomy in young adults with valgus knee
BACKGROUND Musculoskeletal disorders specially knee osteoarthritis are the most common causes of morbidity in old patients. Disturbance of the mechanical axis of the lower extremity is one of the most important causes in progression of knee osteoarthritis. The purpose of the present study was to analyze the surgical results of distal femoral varus osteotomy in patients with genu valgum. METHO...
متن کاملFemoral Bone Plug in Total Knee Replacement.
The intramedullary alignment guides used in total knee replacement disrupt the intramedullary vessels, resulting in greater postoperative blood loss. The use of an autologous bone plug to seal the intramedullary femoral canal has been shown to be effective in reducing postoperative bleeding. The authors present a simple technique to create a bone plug from the anterior chamfer femoral cut to pe...
متن کاملDistal femoral cut in total knee arthroplasty in a Brazilian population☆
OBJECTIVE To determine the ideal angle for making the distal femoral cut in total knee arthroplasty in a Brazilian population. METHODS Panoramic radiographs of the lower limbs bearing weight from 79 patients (57 women and 22 men) were studied, totaling 107 knees with an indication for total knee arthroplasty. The femoral anatomical axis, femoral mechanical axis and cervical-diaphyseal angle w...
متن کاملDistal femoral fractures treated by hinged total knee replacement in elderly patients.
Although the use of constrained cemented arthroplasty to treat distal femoral fractures in elderly patients has some practical advantages over the use of techniques of fixation, concerns as to a high rate of loosening after implantation of these prostheses has raised doubts about their use. We evaluated the results of hinged total knee replacement in the treatment of 54 fractures in 52 patients...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 8 شماره 3
صفحات 463- 464
تاریخ انتشار 2020-05-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023