Development of Prototype Iranian male pelvic phantom for internal dosimetry

نویسندگان

  • Fereshteh Bayani Faculty of Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
چکیده مقاله:

Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between Caucasian and non- Caucasian populations. These phantoms have been used for internal radionuclide dosimetry and other nuclear-medicine applications. Specific absorbed fractions (SAF) are tools for internal dose estimation of radionuclide intake. The differences were due to the racial and anatomical differences in organ mass and inter-organ distance. Many studies have been tried to provide an accurate and reliable data for internal radiation dose calculations. Therefor we construct an Iranian computational phantom to evaluate radiation dose organs within male pelvic region based on Iranian datasets. Internal dosimetry on organ is getting more important from the viewpoint of radiation protection of organ at risk. Materials and Methods: The first version of computational Iranian male pelvis phantom(PIPM) is provided by 5 MRI datasets of Iranian male for precise organ dose calculation, at first organs within pelvic region are segmented by enhancing their margins in each slice, determination of organs volume then, prototype Iranian male pelvis phantom was developed by modifying the equation of internal organs of the ORNL adult phantom finally, this phantom was imported to general purpose Monte Carlo code to simulate photon transport from internal radiation source. Results: The results showed that the individual comparable phantom can be calculated with acceptable accuracy using geometric registration. Comparison of dose calculation for Iranian male pelvic, MIRD and RADAR phantoms showed that differences of self-SAF were affected by organ volume differences. The average of the percent SAF deviation was calculated in testes organ -7.73%, -5.53% for PIMP phantom into MIRD and RADAR phantoms respectively. The largest deviation was observed in urinary bladder organ follow as 37.3%, 52.3% into MIRD and RADAR phantoms and it is shown -23.5% variations in self-SAF prostate organ into MIRD phantom. This phantom could be used for absorbed dose calculation of Iranian male pelvic region with acceptable accuracy in nuclear medicine. Conclusion: A prototype computational Iranian adult male pelvis phantom was represented from 5 Iranian adult males; the results showed that comparable phantom can be calculated internal absorbed dose with significant differences. Accurate voxel phantom is needed for dosimetric simulation in nuclear medicine for malignant tumors in male pelvic region. However, most of the existing voxel phantoms are constructed on the basis of Caucasian or non-Chinese population. It might be provided first Iranian male reference volume organ dataset for future researches.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Iranian Adult Female Reference Phantom for Internal Dosimetry Calculations

Estimation of organ doses in diagnostic and therapeutic nuclear medicine procedures is an area of particular concern for radiation protection, in all over the world. The stylized computational phantoms have contributed significantly to radiation dosimetry in nuclear medicine; however, their simplified treatment of human anatomy is being criticized. Due to the fact that the ICRP adult reference ...

متن کامل

A CVH-based computational female pelvic phantom for radiation dosimetry simulation

Background: Accurate voxel phantom is needed for dosimetric simulation in radiation therapy for malignant tumors in female pelvic region. However, most of the existing voxel phantoms are constructed on the basis of Caucasian or non-Chinese population. Materials and Methods: A computational framework for constructing female pelvic voxel phantom for radiation dosimetry was performed base...

متن کامل

Development of a 9-months pregnant hybrid phantom and its internal dosimetry for thyroid agents

As a consequence of fetal radiosensitivity, the estimation of internal dose received by a fetus from radiopharmaceuticals applied to the mother is often important in nuclear medicine. A new 9-months pregnant phantom based on magnetic resonance (MR) images tied to the International Commission on Radiological Protection (ICRP) reference voxel phantom has been developed. Maternal and fetal organs ...

متن کامل

RC-3a Monte Carlo Simulations for In Vivo Internal Dosimetry (including phantom development)

The radiation doses received by individuals from radionuclides which enter the human body cannot be measured directly but must be inferred. In these calculations several measurable quantities (as the internal whole body burden or urine daily excretion) and quantities derived from models are employed. The Radiation Protection Quantities for internal dosimetry are in principle the same as for ext...

متن کامل

Development of Computed Tomography Head and Body Phantom for Organ Dosimetry

Introduction: Quality assurance in Computed tomography (CT) centers in developing countries are largely hindered by the unavailability of CT phantoms. The development of a local CT phantom for the measurement of organ radiation absorbed dose is therefore requisite. Material and Methods: Local CT phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for...

متن کامل

Design and Development of an Indigenous in-house Tissue-Equivalent Female Pelvic Phantom for Radiological Dosimetric Applications

Introduction: The present study is aimed to design and develop a tissue-equivalent pelvic phantom, mimicking the Indian female pelvic dimensions by means of locally available and cost-effective tissue substitutes having equivalent radiological properties. Materials and Methods: For the purpose of the study, the real female pelvic bones were embedded for preparation. Paraffin wax, Aloe-vera powd...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  183- 183

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023