Development of A New Electrochemical Sensor based on Zr-MOF/MIP for Sensitive Diclofenac Determination
نویسندگان
چکیده مقاله:
In this study, a new molecularly imprinted polymer with nanoporous material of zirconium metal-organic frameworks (Zr-MOF/MIP) for diclofenac (DFC) measurement is presented. The Zr-MOF/MIP was prepared by electropolymerization method, the Zr-MOFs were used to increase electrode surface and the DFC and para- aminobenzoic acid (pABA) were used as template and functional monomer, respectively. Zr--MOFs was characterized by using X-ray powder diffraction (XRD), scanning electron microscope (SEM) and Fourier transform infrared spectroscopy (FTIR). The electrochemical performance was investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Sensor response was evaluated by comparing the electrochemical response of Zr-MOF/MIP, with that of non- Imprinted polymer (NIP), in a 2.0 mM potassium ferrocyanide solution containing 0.2 mM sodium sulfate as probe solution. Measurements were carried out in the potential range of -0.6 to +1.0 V with scan rate of 50 mV/s. The calibration curve of diclofenac was linear in the concentration range of 6.5 μM to 1.5×10+3 μM. Detection limit was obtained 0.1 μM and relative standard deviation of several (n=7) replicate measurements for 1.0 mM DFC concentration has obtained 1.8%. Furthermore, favorable sensitivity, selectivity, good reproducibility and long-term stability, was obtained in the experiment and the proposed electrode was applied for the determination of DFC in pharmaceutical commercial sample with satisfactory results.
منابع مشابه
Fabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate
In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...
متن کاملfabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions
a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...
A New Electrochemical Sensor for Determination of Zolpidem by Carbon Paste Electrode Modified with SnS@SnO2NP
Zolpidem is a drug that is easily attached to the GABA receptors in the brain. This property makes it very effective for tranquilizing as well as hypnagogia. According to the advantages of electrochemical analysis like high selectivity, high sensitivity, low concentration of analyte, cost-effective, portable and easy-to-use setup, they gained high amount of attention among scientists for determ...
متن کاملA Sensitive Electrochemical Sensor for Determination of Imipramine in Urine Sample Using Carbon Ionic Liquid Electrode Modified With Montomorillonite Nanoclay
We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...
متن کاملDesign and Simulation of a New Highly Sensitive Gas Sensor Based on Negative Refraction Photonic Crystal
In this paper, design and simulation of a new highly sensitive gas sensor based on a hybrid photonic crystal (PC) structure, containing negative and positive refractive index sections, is presented. It has been shown that using a PC with negative refraction in the first section, the transmitted power is concentrated on the entrance of the sensing channel, and the transmission of the proposed se...
متن کاملFabrication of a Selective and Sensitive Electrochemical Sensor Modified with Magnetic Molecularly Imprinted Polymer for Amoxicillin
A modified electrochemical sensor for the determination of amoxicillin (AMX) was reported in this paper. The magnetic molecularly imprinted polymer (MMIP) were suspended in AMX solution and then collected on the surface of a magnetic carbon paste electrode (CPE) via a permanent magnet, situated within the carbon paste electrode and then the voltammetry signals were recorded. It was confirmed th...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 12 شماره 3
صفحات 402- 414
تاریخ انتشار 2020-03-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023