Development of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose

نویسنده

چکیده مقاله:

Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the components of human liver tissue, mass percentage, and density, and then simulated by MCNPX code for dosimetry. The real liver tissue was contoured using the computed tomography DICOM images of the abdomen region. Subsequently, the accurate geometry of the segmented liver tissue was generated and simulated by MATLAB software and MCNPX code for dosimetric purposes. Then, the obtained data were transferred into the MCNPX code. Results: Equivalent dose was measured in total and for each component of the liver phantom and separated liver tissue. The results obtained from these two simulations were compared with each other to validate the efficiency of the phantom and evaluated the differences. Conclusion: The comparison of the equivalent doses obtained from the prepared equivalent liver phantom and the real liver tissue revealed the applicability of the liver phantom as a virtual liver for dosimetry.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Computed Tomography Head and Body Phantom for Organ Dosimetry

Introduction: Quality assurance in Computed tomography (CT) centers in developing countries are largely hindered by the unavailability of CT phantoms. The development of a local CT phantom for the measurement of organ radiation absorbed dose is therefore requisite. Material and Methods: Local CT phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for...

متن کامل

Prevalence of Idiopathic Osteosclerosis on Cone Beam Computed Tomography Images

Objectives: This study was performed to investigate the prevalence of idiopathic osteosclerosis on cone beam computed tomography (CBCT) images of patients. Methods: In this descriptive, cross-sectional study, 240 CBCT scans of patients (125 women, 115 men) referred to a private oral and maxillofacial radiology clinic in Tehran in 2013 were selected and evaluated. Presence of idiopathic osteosc...

متن کامل

application of upfc based on svpwm for power quality improvement

در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...

15 صفحه اول

Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners

Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...

متن کامل

A low-cost density reference phantom for computed tomography.

The authors characterized a commercially available foam composed of polyurethane and polyisocyanurate which is marketed for modeling parts in the aircraft, automotive, and related industries. The authors found that the foam may be suitable for use as a density reference standard in the range below -400 Hounsfield units. This range is coincident with the density of lung tissue. The foam may be h...

متن کامل

A Low-Cost Fiducial Reference Phantom for Computed Tomography

To detect the growth in lesions, it is necessary to ensure that the apparent changes in size are above the noise floor of the system. By introducing a fiducial reference, it may be possible to detect smaller changes in lesion size more reliably. We suspend three precision spheres with a precision structure built from pieces from a popular children's building toy. We measure the distances betwee...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره 3

صفحات  183- 191

تاریخ انتشار 2018-07-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023