High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector system and also on the energy of gamma ray, is an important factor in determining the activity of the radioactive sources. A simpler way to determine the activity of radiation sources is to use the virtual point intrinsic efficiency which is independent of source-detector distance. The virtual point is a point within the detector that all interactions are assumed to take place in that point. The goal of this study is to determine the location of the virtual point of the HPGe detector of GMX 40P4-76 model and determine the virtual point intrinsic efficiency for this detector at various energies of gamma rays. To do this, we first experimentally obtained the spectrum of gamma rays emitted from a Europium source at different distances from the detector using the HPGe spectroscopy system. Similarly, using the Monte Carlo simulation method (MCNPX code) we simulated the spectroscopy system. In this study, in the first step, the virtual point distances from detector top were determined in two experimental and simulation methods for gamma ray energies from 121 keV up to 1408 keV, the results of which were in good agreements. In the second step, using the virtual point distances, we calculated the virtual point intrinsic efficiencies at various gamma ray energies for the HPGe detector, and it was shown that this efficiency for a given energy is almost constant with small deviations for various source-detector distances and it is therefore easier to calculate the activity of unknown sources using this efficiency, because the distance dependency is gone and we do not need to perform measurements at different distances.
منابع مشابه
Efficiency determination of HPGe detector by simulation and experimental methods for solid volume source
Analyzes of environmental samples regarding their radioactivity is of important concern for health purposes. We need standard sources to determine radioactive components and their activities. These sources are usually produced regarding type of the sample. One of the fundamental and precise tools to recognize radioactive materials and their activities is HPGe detector. To reach this goal, the d...
متن کاملsimulation and experimental studies for prediction mineral scale formation in oil field during mixing of injection and formation water
abstract: mineral scaling in oil and gas production equipment is one of the most important problem that occurs while water injection and it has been recognized to be a major operational problem. the incompatibility between injected and formation waters may result in inorganic scale precipitation in the equipment and reservoir and then reduction of oil production rate and water injection rate. ...
Gamma-ray imaging with coaxial HPGe detector
We report on the first experimental demonstration of Compton imaging of gamma rays with a single coaxial high-purity germanium (HPGe) detector. This imaging capability is realized by two-dimensional segmentation of the outside contact in combination with digital pulse-shape analysis, which enables to image gamma rays in 4p without employing a collimator. We are able to demonstrate the ability t...
متن کاملdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
Optimization of virtual Frisch-grid CdZnTe detector designs for imaging and spectroscopy of gamma rays
In the past, various virtual Frisch-grid designs have been proposed for cadmium zinc telluride (CZT) and other compound semiconductor detectors. These include three-terminal, semi-spherical, CAPture, Frisch-ring, capacitive Frisch-grid and pixel devices (along with their modifications). Among them, the Frisch-grid design employing a noncontacting ring extended over the entire side surfaces of p...
متن کاملMonte Carlo Determination of Full Energy Peak Efficiency for HPGe Detector and Self-Absorption Correction of Environmental Samples
The Monte Carlo method was used to determine full energy efficiency of a high-purity germanium (HPGe) coaxial detector within an energy range of 53.2-2614 keV. Also, measurement was carried out for a standard Marinelli beaker of 600cm3, which was placed into the reference material of mixed gamma. The plot of the experimentally derived effic...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 8 شماره 4
صفحات 171- 178
تاریخ انتشار 2020-08
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023