Determination of Uterus Absorbed Dose by Patients following Myocardial Perfusion Scan using TLD and Conjugate View Methods
نویسندگان
چکیده مقاله:
Introduction: The determination of patient’s absorbed dose is the first step of radiation protection which depends on the quantification of organ activity in nuclear medicine. The aim of the present study was to determine the absorbed dose by patient’s uterus following myocardial perfusion scan with 99mTC-sestamibi using Theroluminescnce dosimetry (TLD) and conjugate-view methods.Material and Method: In this study, each patient was injected 15 to 20 mCi (based on their weight) of 99mTC-sestamibi. Myocardial perfusion scan from twenty two patients (females) were acquired by gamma camera at 15, 60 and 90 minutes after 99mTC-sestamibi injection. To determine the amount of activity in uterus, conjugate view method was applied on images. Then, MIRD equation was used to estimate absorbed dose in uterus of patients. Moreover, uterus absorbed dose was determined using TLD method. At the end, absorbed dose values obtained in conjugate view method were compared with the data obtained from TLD method.Results: The average amount of uptake for 99mTC-sestamibi by heart was calculated 3.077±0.067 percent of injected dose. The uterus activity at the intervals of 15, 60 and 90 minutes after injection of 99mTC-sestamibi was 0.044±0.015, 0.031±0.014 and 0.026±0.013 mCi, repectively. The uterus absorbed dose per unit of injected activity (mGy/MBq × 10−4) obtained 5.258±0.500 using TLD method.Conclusion: The results of this study were in good agreement with similar studies. Dosimetry using TLD, in comparison with the conjugate view method, demonstrates more accurate results.
منابع مشابه
Evaluation of some blood parameters alteration following low-dose radiation induced by Myocardial Perfusion Imaging
Purpose: With increasing the usage of myocardial perfusion imaging (MPI) for the diagnosis of ischemic heart disease, we aimed to evaluate the side effects of low-dose radiation induced by this technique on blood elements, especially proteins and liver function factors.Materials and Methods: 40 eligible patients (Mean age: 54.6...
متن کاملDetermination and Comparison of Absorbed dose of Ovaries and Uterus in Heart Scan from TC-99 m, by Three Methods: TLD Measurement, MCNP Simulation and MIRD Calculation and Estimation of its Risks
Relation to high absorption fraction of Tc sestamibi by kidneys in heart scan and these organs are near to generation organs (Ovaries and uterus). Urinary system (kidneys and urinary bladder) are specified as sources organs. The main object of this study is to determine the absorbed dose in these critical organs. we have set amount of absorbed fraction radiopharmaceutical in position of kidneys...
متن کاملdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
Two-day stress-rest lower limbs perfusion scan in patients referred for myocardial perfusion imaging
Introduction: Peripheral Vascular Disease (PVD) is a major cause of morbidity and is associated with Coronary Artery Disease (CAD). We aimed to perform Lower Limb Perfusion Scan (LLPS) in patients referred for Myocardial Perfusion Imaging (MPI) and estimate prevalence of PVD in subgroups with normal and abnormal MPI results. We also compared quantitative indices of LLPS in pati...
متن کاملAn Assessment of Spinal Cord Dose Following Radiotherapy of Nasopharyngeal Cancer by TLD and Rando Phantom
Introduction: Nasopharyngeal carcinoma is one of the most common malignancies in the head and neck region and radiotherapy is its treatment of choice. In spite of the fact that it is widely used, due to the presence of many sensitive organs or tissues in this region, patients may suffer from a wide range of side effects. One such sensitive tissue is the spinal cord. If the absorbed dose to spin...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 9 شماره 4
صفحات 445- 452
تاریخ انتشار 2019-08-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023