Determination of two capsaicinoids in analgesic transdermal patches using RP-HPLC and UV spectroscopy
نویسندگان
چکیده مقاله:
Background and objectives: At the present time, a considerable frontier in the administration of therapeutic medications is transdermal drug delivery. Methods: In this study, a rapid, precise, sensitive and selective reversed-phasehigh performance liquid chromatography (RP-HPLC) method has been evaluated, developed and validated to separate and quantitate capsaicin and dihydrocapsaicin (main active agents) in analgesic dermal patches produced in Iran. Results: After isolation from laminated adhesive patches, capsaicinoids were analyzed on Lichrospher C18 analytical columns with reversed phase, using a mobile phase composition of methanol and distilled water (70:30 v/v) and without any buffer (pH=6.5). The flow rate was 1 mL/min and the UV detector was operating at 281 nm. The assay was found to be linear over the range of 0.1-1.0 mg/mL. All validation parameters were within the acceptable range. Conclusion: It seems that the developed method was fairly sensitive and reliable in measuring capsaicinoids in commercially available analgesic transdermal patches in Iran.
منابع مشابه
Quantitative Determination of Ciprofibrate in Tablets by Derivative UV Spectroscopy and RP-HPLC Method
A derivative UV spectrophotometric and a reversed phase high-performance liquid chromatographic method for the determination of ciprofibrate in tablets was developed. The first-order derivative UV spectrophotometric method was found to be accurate with 100.57±0.97 recovery and precise with a coefficient of variation of 1.44. These results were compared to those obtained by reference methods, ze...
متن کاملDetermination of Carboxylic Acids in Apple Juice by RP HPLC
Low molecular weight organic acids are most predominant in apple juice among these components fumaric acid was not exceed more than 5 ppm. It was thought that the HPLC is the best method of the determination of organic acids in the apple juice. In this study, chromatographic separation of organic acids of apple juice was obtained by preparing a sample and by applying them to acid phase for ...
متن کاملDevelopment and Validation of UV Spectroscopy and RP - HPLC Methods for Estimation of
International Journal of Pharmaceutical Sciences Review and Research Available online at www.globalresearchonline.net © Copyright protected. Unauthorised republication, reproduction, distribution, dissemination and copying of this document in whole or in part is strictly prohibited. © Copyright protected. 16 Saroj Jain, Anupama Diwan, Satish Sardana Department of Pharmaceutics, Hindu College of...
متن کاملDevelopment and Validation of RP-HPLC-UV Method for Determination of Diclofenac Sodium Residues on Surfaces for Cleaning Validation
In recent years, cleaning validation has achieved a position of increasing in the pharmaceutical industry. It provides assurance to the cleaning procedure that ensures equipment is consistently cleaned from the product, detergent and microbial residues to an acceptable level to avoid cross-contamination and adulteration of drug product with other active ingredients. The aim of this study was to...
متن کاملSimultaneous Estimation of Olmesartan and Atorvastatin in Bulk and Fromulation by Using Uv Spectroscopy and Rp-hplc
Volume 1(2) March-April 2013 Page 244 SIMULTANEOUS ESTIMATION OF OLMESARTAN AND ATORVASTATIN IN BULK AND FROMULATION BY USING UV SPECTROSCOPY AND RP-HPLC Revanth Reddy B * , Aravind G Nimra college of pharmacy, Vijayawada *Corresponding author: E.mail: [email protected] ABSTRACT Simple, rapid and accurate UV Spectroscopic (Simultaneous Equation method and First order derivative method) a...
متن کاملRP-HPLC-UV Method for Simultaneous Determination of Nine Isoflavonoids in Huangqi-Gegen Herbal Pair
A new simple and efficient RP-HPLC-UV method was developed for the simultaneous analysis of nine isoflavonoids in Huangqi-Gegen herbal pair. Effective chromatographic separation of these components was achieved on a Kromasil C18 column (4.6×250 mm, i.d.; 5 μm) with gradient elution of methanol and 0.2% formic acid aqueous solution at a flow rate of 1.0 mL/min in 60 min. Detection was performed ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 4 شماره Supplement
صفحات 72- 72
تاریخ انتشار 2017-11-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023