Determination of reference ranges using medical laboratory date

نویسندگان

  • A Kiyani
  • H Rahi Assistant professor
چکیده مقاله:

In order to have reliable reference ranges and to minimize the effects of variables such as the procedure of specimen collection, geographical location, dietary habits, life style and possible errors during the performance of tests, it  is recommended that each medical laboratory establish it's own reference values. Idealy, the reference ranges Should be determined by analysis of specimens from every or, from a random sample of the individuals in the population of interest. However, in terms of time and money, it is very expensive and impracticable to examine and apply the selection criteria to the entire population and therefore a random selection of a subset of individuals is recommended. As an alternative, a number of methods have been suggested where by the test results of individuals undergoing routine analysis can be used to establish reference values. These people are a pt to forma heterogeneous sample, I.e. a mixture of two distributions, one, of healthy and one, of sick individuals. For this reason and the fact that in our country almost all clinical laboratories are using reference ranges belonging to foreign sources, a special computer program was devised to analyse the data collected at Kermanshah central laboratory. A set of reference values for routine and special biochemical tests have been derived. This includes; Glucose 55-119 mg/ dl, BUN 6-20 mg/ dl, cholesterol 138-278 mg/ dl, triglyceride 57-156 mg/ dl, creatinine 0.45-1.2 mg/ dl, uric acid 2.8-7.1 mg/ dl, total bilirubin 0.39-1.2 mg/ dl, direct bilirubin 0.18-0.23 mg/ dl, calcium 8.5-10.4 mg/ dl, phosphorus 2.5-5.6 mg/ dl, sodium 138-143 mmol/ L, potassium 3.8-4.8 mmol/L, iron 68-165 ug/ dl, Hb 10.2-16.8 G/ dl, total protein 6.6-7.1 G/ dl, SGOT 9-27U/ L, SGPT 8.26 U/ L, T 3.93-12.41 ug/ dl, T3 – Uptake 23-32℅, FTI 1.3-3.8℅mg/ dl, TSH 0.36-3.13 uIU/ ml. This results were compared with the reference ranges established by kitmanufacturers. The results of glucose, cholesterol and HB estimation have also been compared with the values calculated for a random samples selected by the health survey of Iran in Kermanshah province.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Plasma Concentration Reference Ranges for Risperidone and Paliperidone

Schizophrenia is a common disease managed by a range of interventions, with the primary treatment being antipsychotic medications (APS). Inadequate response, lack of adherence, and/or adverse events often prevent optimal therapeutic effects or therapeutic efficiency. Monitoring APS plasma concentrations can be used together with a full clinical evaluation to help improve patient care or offer b...

متن کامل

Fructosamine Clinical Usefulness and Determination of Reference Ranges

Fructosamine measurement, on the other hand, exploits the ability of serum proteins to undergo glycation (glycosylation) in conditions of increased ambient glycemia. Glycated proteins are an accepted measure of intermediate glycemia2,3 as demonstrated by the well established clinical usage of hemoglobin A determinations. Serum proteins are glycated as well, and determinationlc of their values r...

متن کامل

Determination of Age-Dependent Reference Ranges for Coagulation Tests Performed Using Destiny Plus

BACKGROUND In order to apply the right treatment for hemostatic disorders in pediatric patients, laboratory data should be interpreted with age-appropriate reference ranges. OBJECTIVES The purpose of this study was to determining age-dependent reference range values for prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen tests, and D-dimer tests. MATERIALS AND ME...

متن کامل

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

Comprehensive Reference Ranges for Hematology and Clinical Chemistry Laboratory Parameters Derived from Normal Nigerian Adults

BACKGROUND Interpretation of laboratory test results with appropriate diagnostic accuracy requires reference or cutoff values. This study is a comprehensive determination of reference values for hematology and clinical chemistry in apparently healthy voluntary non-remunerated blood donors and pregnant women. METHODS AND FINDINGS Consented clients were clinically screened and counseled before ...

متن کامل

Adult Hematology and Clinical Chemistry Laboratory Reference Ranges in a Zimbabwean Population

BACKGROUND Laboratory reference ranges used for clinical care and clinical trials in various laboratories in Zimbabwe were derived from textbooks and research studies conducted more than ten years ago. Periodic verification of these ranges is essential to track changes over time. The purpose of this study was to establish hematology and chemistry laboratory reference ranges using more rigorous ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 1  شماره 1

صفحات  1- 11

تاریخ انتشار 1994-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023