Determination of Protein Concentration Using Bradford Microplate Protein Quantification Assay

نویسندگان

  • Masoumeh Ahmadizadeh School of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, IR Iran
  • Moulood Valipour Noroozi Student Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, IR Iran
  • Rouhollah Valipour Nouroozi Parasitology Department, Medical school, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, IR Iran
چکیده مقاله:

Background: Bradford protein assay is popular due to its ease of performance and relative sensitivity. Many researchers and laboratories in Iran use standard assay of Bradford by cuvette. No commercial kit was available for Bradford microplate assay in Iran. Meanwhile, imported Bradford commercial kits are very expensive and have a long delivery time in Iran. Till now no study or document on Bradford microplate protein quantification assay was reported in Iran, so this study aimed to design and carried out this assay. Methods: In the current study, antigen B of hydatid cyst fluid was used as sample and the assay was performed in microplate wells. The absorbance values were measured at 595 nm and standard curve was generated by Microsoft Office Excel software. The protein concentration of sample was calculated using the equation of the standard curve. Results: Average protein concentration of the sample was 1175 &mug/ml. The total time needed for reading of absorbance was two minutes approximately. Conclusion: Bradford microplate protein assay is a fast and suitable method. This method could be replacing the time consuming method with cuvette. In addition, if this assay produces as a low price kit it could have many benefits for students and laboratories that need to determine protein concentration by Bradford assay.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

determination of protein concentration using bradford microplate protein quantification assay

background: bradford protein assay is popular due to its ease of performance and relative sensitivity. many researchers and laboratories in iran use standard assay of bradford by cuvette. no commercial kit was available for bradford microplate assay in iran. meanwhile, imported bradford commercial kits are very expensive and have a long delivery time in iran. till now no study or document on br...

متن کامل

Linearization of the bradford protein assay.

Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromi...

متن کامل

Relative Quantification of Protein-Protein Interactions Using a Dual Luciferase Reporter Pull-Down Assay System

The identification and quantitative analysis of protein-protein interactions are essential to the functional characterization of proteins in the post-proteomics era. The methods currently available are generally time-consuming, technically complicated, insensitive and/or semi-quantitative. The lack of simple, sensitive approaches to precisely quantify protein-protein interactions still prevents...

متن کامل

Assays for determination of protein concentration.

Biochemical analysis of proteins relies on accurate quantitation of protein concentration. This unit describes how to perform commonly used protein assays, e.g., Lowry, Bradford, BCA, and UV spectroscopic protein assays. The primary focus of the unit is assay selection, emphasizing sample and buffer compatibility. Protein assay standard curves and data processing fundamentals are discussed in d...

متن کامل

Microvolume Protein Concentration Determination using the NanoDrop 2000c Spectrophotometer

Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of...

متن کامل

A Microplate-Based Nonradioactive Protein Synthesis Assay: Application to TRAIL Sensitization by Protein Synthesis Inhibitors

Non-radioactive assays based on incorporation of puromycin into newly synthesized proteins and subsequent detection using anti-puromycin antibodies have been previously reported and well-validated. To develop a moderate- to high-throughput assay, an adaptation is here described wherein cells are puromycin-labeled followed by simultaneously probing puromycin-labeled proteins and a reference prot...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 4  شماره None

صفحات  11- 17

تاریخ انتشار 2015-09

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023