Determination of Nicotinic Acid by Square Wave Voltammetry on a Carbon Paste Electrode: the Crucial Effect of Electrode Composition and Analytical Conditions

نویسندگان

  • Somayeh Amjadi
  • Taher Alizadeh Department of Analytical Chemistry, Faculty of Chemistry, University College of Science, University of Tehran, Tehran, Iran P.O. Box 14155-6455, Tehran, Iran
چکیده مقاله:

The foregone studies have shown that nicotinic acid cannot produce noticeable reductive signal at carbon-based electrodes without appropriate modification of the electrode. This is an obvious reason that mercury is known as the main electrode material for electro-reduction of nicotinic acid. In this study, it has been shown that it is possible to create a remarkable reduction signal for NA at a carbon paste electrode (CPE) without any modification. This achieved by precisely adjustment of electroanalysis pH, appropriately choosing of binder kind, precisely controlling of the percentage of the binder in the electrode composition and utilizing of an effective voltammetric technique. A carbon paste electrode, containing 30% of n-eicosane (as binder) was shown to be the best electrode for NA determination. It was also shown that utilizing of square wave voltammetry in place of differential pulse voltammetry led to remarkably improvement in the analytical signal of NA. The pH value of the electroanalysis solution was shown to be a crucially effective factor for creating of NA signal and an optimum value of pH equal to 2.2 was chosen as the best pH condition. The optimized method exhibited a dynamic concentration linear range of 3.0×10−6-3.0×10−3 molL-1 with a detection limit of 5.63×10−7 molL-1. As an analytical application, the proposed sensor was successfully used for determination of nicotinic acid in the urine, serum and pharmaceutical samples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Riboflavin by Nanocomposite Modified Carbon Paste Electrode in Biological Fluids Using Fast Fourier Transform Square Wave Voltammetry

Herein, fast Fourier transformation square-wave voltammetry (FFT-SWV) as a novel electrochemical determination technique was used to investigate the electrochemical behavior and determination of Riboflavin at the surface of a nanocomposite modified carbon paste electrode. The carbon paste electrode was modified by nanocomposite containing Samarium oxide (Sm2O3)/reduced gra...

متن کامل

Determination of Quercetin in a Pharmaceutical Sample by Square-Wave Voltammetry Using a Poly(vinylpyrrolidone)-Modified Carbon-Paste Electrode

Um eletrodo de pasta de carbono modificado com o polímero poli(vinilpirrolidona) foi avaliado para o estudo eletroquímico e a determinação eletroanalítica da quercetina. Sobre este eletrodo, voltamogramas cíclicos da quercetina apresentaram três picos de oxidação localizados em +0,32, +0,78 e +1,04 V. A eletro-oxidação no primeiro pico conduz à formação da orto-quinona correspondente, a qual po...

متن کامل

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

متن کامل

Simultaneous Determination of Ascorbic Acid, Uric Acid and Tryptophan by Novel Carbon Nanotube Paste Electrode

In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...

متن کامل

electro-oxidation mechanism and direct square-wave voltammetric determination of lidocaine with a carbon-paste electrode

conclusions the results of this study show that lh in different pharmaceutical preparations could be determined with good reliability. in addition, the results reveal that the equal numbers of electrons and protons are involved in the oxidation of lh and the irreversible oxidation of an analyte was performed via amine groups of lh molecule. background lidocaine hydrochloride (lh) is one of the ...

متن کامل

Electro-Oxidation Mechanism and Direct Square-Wave Voltammetric Determination of Lidocaine With a Carbon-Paste Electrode

BACKGROUND Lidocaine hydrochloride (LH) is one of the most extensively used local anesthetics and peripheral analgesics. Availability of a simple and sensitive assay method for this analyte in pharmaceutical preparations as well as development of new voltammetric detectors that can be applied in chromatographic systems for determination of this analyte in biological samples are of great importa...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 12  شماره 2

صفحات  250- 262

تاریخ انتشار 2020-02-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023