Manganese plays a key role in the health of human beings therefore, its determination is very important in medical fields. In this regards, a novel coated graphite electrode was constructed for determination of manganese (II) by using zolpidem as an ionophore, for the first time. The best performance was obtained of the membrane composition of PVC (32%), Potassium tetrakis (4-chlorophenyl) borate (3%) as ionic additive, zolpidem (10%) as ionophore and Dioctyl phthalate (55%) as Plasticizer. The linear working range of the potentiometric sensor was from 1×10-7 to 1×10-2 Mol L-1. The electrode shows an exquisite Nernstian slope value of 29.7 mV.Decade-1 and its limit of detection was 9×10-8 Mol L-1. The potential response of the membrane sensor was also evaluated in non aqueous mediums and it was found out that the electrode can also be used in systems that are entailed of 15% of ethanol and acetone organic solvents. The selectivity subject was also inspected by matched potential method over 20 different cations and the electrode demonstrates an eminent selectivity toward Mn2+ over all of the studied cations. In the end, the applicability of the electrode in the determination of Mn2+ in dietary supplements as real samples was investigated.
منابع مشابه
Determination of Cobalt(II) by a New PVC Membrane Coated Graphite Electrode Based on 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier
Cobalt has great biological effects on human beings and also other living organisms, hence its determination is very important. In this regard, a novel coated graphite electrode was designed for determination of Co2+ ions by exploiting 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier, for the first time. The foremost function was witnessed from the membrane composition of PVC...
متن کاملDetermination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore
In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...
متن کاملChromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier
A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...
متن کاملA mercury(II) ion-selective electrode based on N,N-dimethylformamide-salicylacylhydrazone as a neutral carrier.
A new PVC membrane mercury(II) ion electrode based on N,N-dimethylformamide-salicylacylhydrazone (DMFAS) as an ionophore is described, which shows excellent potentiometric response characteristics and displays a linear log[Hg(2+)] versus EMF response over a wide concentration range between 6.2 x 10(-7) and 8.0 x 10(-2) M with a Nerstian slope of 29.6 mV per decade and a detection limit of 5.0 x...
متن کاملNovel ZrO2 ion-selective electrode based on 4,7,13,16,21,24-hexa oxa- 1,10- diazabicyc1o[8,8,8]-hexa cosane as neutral carrier in PVC matrix
In this work, a novel Zr02+ PVC-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (HODBHC) as a new ionophore is presented. The sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 M, with a near Nernstian slope of 29.9 ± 0.4 mV per decade in an acidic solution(pH=1). The limit of detection is 8.0 x 1 0 7 M. The electrodes possess adv...
متن کاملA Novel Coated Graphite Electrode for Potentiometric Determination of Pyrilamine Maleate in Pharmaceutical Compounds and Biological Fluids
A new pyrilamine coated graphite electrode (CGE) based on pyrilamine-tetraphenylborate ion-pair (Pyra-TPB) as electroactive material has been described. The sensor exhibited a linear response with a good Nernstian slope over a relatively wide range of concentration. The membrane film of the electrode made of 3% (w/w) ion-pair, 48.5% DBP (w/w) and 48.5% PVC (w/w). The sensor displays Nernstian r...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 5 شماره 2
صفحات 273- 284
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023