Determination of human absorbed dose from [153Sm]-Samarium maltolate based on distribution data in rats

نویسندگان

  • A. Hakimi Department of Energy Engineering and Physics, Amir Kabir University of Technology, Tehran, Iran
  • A.R. Jalilian Nuclear Science and Technology Research Institute, Tehran, Iran
  • H. Rezaeejam Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran
  • M. Ghannadi-Maragheh Nuclear Science and Technology Research Institute, Tehran, Iran
  • P. Abbasian Department of Energy Engineering and Physics, Amir Kabir University of Technology, Tehran, Iran
  • S. Shirvani-Aran Nuclear Science and Technology Research Institute, Tehran, Iran
چکیده مقاله:

Background: Therapeutic radiopharmaceuticals are designed to deliver high doses of radiation to selected target organs with an aim of minimizing unwanted radiation to surrounding healthy tissue. Due to the potential of targeted radiotherapy to treat a wide range of malignant conditions, [153Sm]-samarium maltolate was developed for possible therapeutic applications. Materials and Methods: The organ radiation-absorbed doses have been evaluated for human based on animal data. After intravenous administration of 153Sm-Mal to four groups of rats, they were sacrificed at exact time intervals and the percentage of injected dose per gram of each organ was calculated by direct counting from rat data. Then S values for 153Sm by using specific absorbed fractions were calculated. By taking advantage of the formulation that Medical Internal Radiation Dose suggests, radiation-absorbed doses for all organs were calculated and extrapolated from rat to human. Results: From rat data, it is estimated that a 185-MBq injection of 153Sm-Mal into a human might result in the highest absorbed dose in the lymphoma tissues (liver 176.3, lungs 68, spleen 66.8 and sternum 19 mGy), especially in liver respect to the other tissues. Conclusion: These results suggest 153Sm-Mal as an efficiently new therapeutic agent in order to overcome possible lymphatic malignancies.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

determination of human absorbed dose from [153sm]-samarium maltolate based on distribution data in rats

background: therapeutic radiopharmaceuticals are designed to deliver high doses of radiation to selected target organs with an aim of minimizing unwanted radiation to surrounding healthy tissue. due to the potential of targeted radiotherapy to treat a wide range of malignant conditions, [153sm]-samarium maltolate was developed for possible therapeutic applications. materials and methods: the or...

متن کامل

Human organ absorbed dose estimation of 166Ho-BPAMD complex based on biodistribution data of male Syrian rats

Introduction: Recently, 166Ho-BPAMD was introduced as a suitable agent for bone marrow ablation. The aim of this study was to estimate the absorbed dose of this novel agent in the human organs which is necessary before the clinical application. Methods: 166Ho was produced by direct irradiation of 165Ho in the research reactor. 250 µg...

متن کامل

Preparation and Quality Control of the [153Sm]-Samarium Maltolate Complex as a Lanthanide Mobilization Product in Rats

Development of lanthanide detoxification agents and protocols is of great importance in management of overdoses. Due to safety of maltol as a detoxifying agent in metal overloads, it can be used as a lanthanide detoxifying agent. In order to demonstrate the biodistribution of final complex, [(153)Sm]-samarium maltolate was prepared using Sm-153 chloride (radiochemical purity >99.9%; ITLC and sp...

متن کامل

Determination of internal absorbed dose from radiation of 111In-Rituximab in body

Introduction: There are many ways to treat cancer and pain relief. One of the methods is radiopharmaceutical therapy. Indium 111-rituximab contains the radioisotope indium-111 and rituximab. The Indium-111, after decay, emits gamma rays with energies of 245 KeV and 171 KeV, and beta-radiation of 26 KeV. In this study, the absorbed dose of 111In-Rituximab in human body was calcu...

متن کامل

Human Absorbed Dose Estimation of a New IN-111 Imaging Agent Based on Rat Data

The measurement of organ radiation exposure dose is one of the most important steps to be taken initially, for developing a new radiopharmaceutical. In this study, the dosimetric studies of a novel agent for SPECT-imaging of the bone metastasis, 111In1,4,7,10-tetraazacyclododecane-1,4,7,10 tetraethylene phosphonic acid (111In-DOTMP) complex, have been carried out to estimate the dose in human o...

متن کامل

the effect of aqueous extract of garlic on formalin-induced pain in male rats

چکیده اثر عصاره آبی سیر بر درد ناشی از آزمون فرمالین در موش صحرایی نر به کوشش نرگس اسکندری روزبهانی زمینه و هدف: گیاه سیر از خانواده لیلیاسه و گونهallium sativum بومی آسیای میانه بوده و از دوران ،باستان تاکنون به خواص درمانی متفاوت آن مثل: کاهندگی قندخون، کلسترول خون، فشار خون، اثرات مفیدآن بر دستگاه قلبی عروقی و بیماریهای انعقادی خون، اثرات آنتی اکسیداتیو، درمان بیماریهای تنفسی وگوارشی، ا...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 13  شماره None

صفحات  173- 180

تاریخ انتشار 2015-04

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023