Determination of Cobalt(II) by a New PVC Membrane Coated Graphite Electrode Based on 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier
نویسندگان
چکیده مقاله:
Cobalt has great biological effects on human beings and also other living organisms, hence its determination is very important. In this regard, a novel coated graphite electrode was designed for determination of Co2+ ions by exploiting 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier, for the first time. The foremost function was witnessed from the membrane composition of PVC (29%), Potassium tetrakis (4-chlorophenyl) borate (2%) as an ionic additive,6-chloro-11-azabenzo[a]phenothiazin-5-one (9%) as ionophore and Dioctylphthalate (60%) as Plasticizer. The linearity domain of the membrane sensor was from 5×10-7 to 1×10-2 Mol L-1 with the Nernstian slope value of 30.1 mV.Decade-1. The potential response of the designed electrode was also investigated in non-aqueous mediums and it was found out that the electrode is also able to be used in systems that are entailed of 20% of ethanol and acetone organic solvents. The response time and lifespan of the electrode was 5 S and 3 months respectively. The sensor selectivity was also evaluated by match potential method over other cations and it shows an eminent selectivity towards Co2+ over all of the inspected ions. The applicability of the electrode in the potentiometric titration with EDTA was also investigated. In the end, the proposed electrode was utilized for determination of Co2+ in four aqueous specimens as real samples.
منابع مشابه
Determination of Mn2+ in Pharmaceutical Supplements by a Novel Coated Graphite Electrode Based on Zolpidem as a Neutral Ion Carrier
Manganese plays a key role in the health of human beings therefore, its determination is very important in medical fields. In this regards, a novel coated graphite electrode was constructed for determination of manganese (II) by using zolpidem as an ionophore, for the first time. The best performance was obtained of the membrane composition of PVC (32%), Potassium tetrakis (4-chlorophenyl) bora...
متن کاملDetermination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore
In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملA new lead(II)-selective PVC-coated graphite rod electrode based on a Schiff base complex.
A new lead(II)-selective electrode has been developed based on bis(acetylacetone)-p-phenylenediamine-lead(II) [LPb(NO3)2]H2O complex ionophore as a sensing material, dioctylphthalate (DOP) as a solvent mediator and PVC as a matrix. This electrode exhibits a linear Nernstian response over the concentration range of 1 x 10(-5)-1 x 10(-1) mol l(-1) of Pb(II) cation, with a cationic calibration slo...
متن کاملChromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier
A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...
متن کاملselective membrane electrode for bromide ion based on aza pyrilium ion derivative as a new ionophore.
a highly selective electrode for bromide ion based on aza pyrilium derivative as an excellentionophore is described.the sensor exhibits a good linear response with a slope of ( 60±1 ) mv per decadeover the concentration range of ( 1×10-3 – 9×10-6 m ) , and a detection limit of ( 3×10-6 m ) of bromideions .the electrode response is independent of ph in the range of(4.0 –9.5).selectivity coeffici...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 13 شماره 2
صفحات 18- 35
تاریخ انتشار 2019-05-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023