Background: In many clinical situations, knowledge of central venous pressure (CVP) is important. Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery. Those with carotid artery or jugular venous diseases as well as those with glaucoma or cardiac ejection fraction of less than 50% were excluded from the study. Results: A linear correlation was found between CVP and IOP (r = 0.66, p<0.001). CVP can be easily derived by halving the IOP. Conclusion: The use of this very simple method, particularly in those health care centers where due to the lack of necessary equipment for accessing central veins, CVP measurement is not possible, may provide useful information to physicians.
منابع مشابه
determination of central venous pressure from intraocular pressure
background: in many clinical situations, knowledge of central venous pressure (cvp) is important. measurement of cvp is not always possible. objective: to determine if intraocular pressure (iop) can be used as an estimate for cvp. methods: iop and cvp were measured concurrently in 30 candidates of coronary artery bypass graft surgery. those with carotid artery or jugular venous diseases a...
متن کاملIntraocular Pressure Reduction Is Associated with Reduced Venous Pulsation Pressure
PURPOSE To explore whether alterations in intraocular pressure (IOP) affect vein pulsation properties using ophthalmodynamometric measures of vein pulsation pressure. PATIENTS AND METHODS Glaucoma patients had two retinal vein pulsation pressure (VPP) measurements from upper and lower hemiveins performed by ophthalmodynamometry at least 3 months apart. All subjects had VPP and IOP recorded at...
متن کاملperipheral venous pressure as a predictor of central venous pressure in continuous monitoring in children
متن کامل
Influence of tissue pressure on central venous pressure/peripheral venous pressure correlation: An experimental report.
BACKGROUND Peripheral venous pressure (PVP) has been shown to correlate with central venous pressure (CVP) in a number of reports. Few studies, however, have explored the relationship between tissue pressure (TP) and PVP/CVP correlation. METHODS PVP and CVP were simultaneously recorded in a bench-top model of the venous circulation of the upper limb and in a single human volunteer after under...
متن کاملContinual monitoring of intraocular pressure: effect of central venous pressure, respiration, and eye movements on continual recordings of intraocular pressure in the rabbit, dog, and man.
A new method has been devised for continual monitoring of intraocular pressure by radiotelemetry. The use of this instrument for monitoring intraocular pressure by a variety of ophthalmic conditions is described.
متن کاملIntraocular pressure and central corneal thickness.
From the results of the Ocular Hypertension Treatment Study emerged the conclusion that ocular hypertensive subjects with thinner central corneal thickness (CCT) are at increased risk of developing glaucoma. Although possible underlying biases that could have led to this conclusion are still under investigation, there is an increasing interest in the scientific community to understand the poten...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 28 شماره 2
صفحات 72- 74
تاریخ انتشار 2015-10-28
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023