Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection

نویسندگان

چکیده مقاله:

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important parameters, such as extraction and disperser solvent and volume of them, extraction time, pH and salt effect were investigated. Under optimized conditions, a linear relationship was obtained in the range of 1.0-300.0 mg l-1. The method detection limit was 0.1 mg l-1. The relative standard deviations for the analysis of 2-phenylethanol were in the range of 1.5-2.4%. The relative recoveries of 2-phenylethanol at spiking levels of 10, 75 and 150 mg l-1 were 93.7, 96.9 and 97.2%, respectively. The enrichment factor of the proposed method was 123. The proposed method is a simple, fast, accurate, highly stable and selective and was applied for determination of 2-phenylethanol in rose water sample with satisfactory results.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

determination of 2-phenylethanol in rose water using dispersive liquid-liquid microextraction with gas chromatography flame ionization detection

a simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (dllme) coupled with gas chromatography-flame ionization detection (gc-fid) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. in the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. some important pa...

متن کامل

Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....

متن کامل

Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

OBJECTIVES Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. MATERIALS AND METHODS Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1.0;...

متن کامل

Separation and determination of amitriptyline and nortriptyline by dispersive liquid-liquid microextraction combined with gas chromatography flame ionization detection.

Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was applied for the determination of two tricyclic antidepressant drugs (TCAs), amitriptyline and nortriptyline, from water samples. This method is a very simple and rapid method for the extraction and preconcentration of these drugs from environmental sample solutions. In this m...

متن کامل

determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

objective(s): dispersive liquid-liquid microextraction coupled with gas chromatography (gc)-flame ionization detector was developed for the determination of valproic acid (vpa) in human plasma. materials and methods: using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing vpa (ph, 1.0...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 3  شماره 1

صفحات  131- 138

تاریخ انتشار 2016-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.