DETECTION OF CROSS-LINmD PERIDES BY FAST ATOM B01WBARDMENT MASS SPECTROMETRY

نویسندگان: ثبت نشده
چکیده مقاله:

The possibility of chemical modification of peptides and proteins under the condition of proteolytic digestions and FABMS analysis was investigated. The results ;indicate that among the amino acid constituents of peptides and proteins: serinefcysteine, and cystine are the most sensitive residues which undergo chemical modificadons under the exprimenta1 conditions. The chemical modification of these amino acids which is governed by the intrinsic properties of the peptides will result in the formation of a molecular ion mass which is 16 mu lower than the molecufitir ion of the parent peptide, MHf. Exact mass measurements of (MH-16) molecular ions indicate that these ions may cornspond to(MH-H O +H ) but not(MH-CH ) molecules. In addition, the results indicate the presence of no inter-and /or intrachain disulfide bond rearrangements uhder the experimental conditions of degradations and FABMS analyses of Lysozyme and Rihonuclease A.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

detection of cross-linmd perides by fast atom b01wbardment mass spectrometry

the possibility of chemical modification of peptides and proteins under the condition of proteolytic digestions and fabms analysis was investigated. the results ;indicate that among the amino acid constituents of peptides and proteins: serinefcysteine, and cystine are the most sensitive residues which undergo chemical modificadons under the exprimenta1 conditions. the chemical modification of t...

متن کامل

Fast - atom - bombardment mass spectrometry

A detailed study of the mass spectra of peptides produced by the new technique of fast-atom bombardment is reported. Molecular weights of unmodified peptides containing up to 21 amino acids have been determined. In favourable cases, the molecular-weight determination may be made on as little as 0.1 nmol of sample. Positive-ion and negative-ion spectra are obtained with equal facility. With samp...

متن کامل

FAST ATOM BOMBARDMENT MASS SPECTROMETRY (FABMS) ANALYSIS OF AN N- TERMINAL - BLOCKED PEPTIDE

FABMS analysis of T-lb peptide before and after one cycle of Edman degradation indicated an unblocked N-terminal Thr residue for this tryptic peptide. In contrast , our data showed a molecular protonated ion, MH + for T- la peptide at 655 mass units (mu) which is 42 mu higher than the MH ion of T- 1b peptide. In addition, T- la peptide was not amenable to one cycle of manual Edman degrada...

متن کامل

Continuous-flow fast atom bombardment mass spectrometry.

The continuous-flow fast atom bombardment probe performs equally well with or without a high-performance liquid chromatography column producing clean spectra containing little or no background noise. Its function as a liquid chromatography-mass spectrometry interface for labile and involatile samples has been illustrated with reference to dansylated amino acids. The versatility of the new probe...

متن کامل

C-terminal peptide identification by fast atom bombardment mass spectrometry.

A previously described technique [Rose, Simona, Offord, Prior, Otto & Thatcher (1983) Biochem. J. 215, 273-277] permits the identification of the C-terminal peptide of a protein as the only peptide that does not incorporate any 18O upon partial enzymic hydrolysis in 18O-labelled water. Formation of chemical derivatives followed by combined g.l.c.-m.s. was used in this earlier work. We now descr...

متن کامل

fast atom bombardment mass spectrometry (fabms) analysis of an n- terminal - blocked peptide

fabms analysis of t-lb peptide before and after one cycle of edman degradation indicated an unblocked n-terminal thr residue for this tryptic peptide. in contrast , our data showed a molecular protonated ion, mh + for t- la peptide at 655 mass units (mu) which is 42 mu higher than the mh ion of t- 1b peptide. in addition, t- la peptide was not amenable to one cycle of manual edman degradation. ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 2  شماره 2

صفحات  -

تاریخ انتشار 1991-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023