Designing a specific upper body anaerobic power test for wrestling
نویسندگان
چکیده مقاله:
Abstract The aim of this study was designing a specific upper body anaerobic power test for wrestlers and determining validity, reliability and objectivity of the designed test. In order to assess the anaerobic power of wrestlers on the basis of upper body Wingate test, Twenty two wrestlers (age=23/40±3/20 year, height=173/13±6/97 cm, weight=74/55±3/88 kg) of Tehran wrestling team (most of them were Asian champion) were participated in this study. Mean, maximum and minimum of anaerobic power and fatigue indices assessed by both tests. In order to analysis the correlation between power indices and physiological indices (blood lactate and heart rate), Pearson correlation has been used, and the differences between blood lactate after 2 min in both tests assessed. The result indicated that there was significant correlation between maximum (p=0/001 r=0/739), mean (p=0/001 r=0/670) and minimum (p=0/01 r=0/650) of power and fatigue indices (p=0/003 r=0/610) obtained by designed test and Wingate test. The result showed that there was significant correlation between heart rate immediately after doing both tests (p=0/001, r=0/705) and also the result show that there was not significant correlation between blood lactate after 2 min. of doing both tests (p=0/07 r=0/353). Statistical analyses also showed no difference between the blood lactate after 2 min of doing both tests. Analyzing the validity of designed test, revealed that there was significant correlation between max (p=0/000 r=0/840), mean (p=0/000 r=0/861) and minimum (p=0/000 r=0/830) power and fatigue indices (p=0/000 r=772) after performing twice of designed test. In analysis objectively of the designed test, the result revealed that there was significant correlation between max (p=0/000 r=0/832), mean (p=0/000 r=0/858) and minimum (p=0/000 r=0/805) power and fatigue indices (p=0/000 r=0/832) which was done by two different tester. It can be concluded that in respect to Wingate upper body test, the designed test in this study is valid and reliable test to measure the anaerobic power of wrestlers.
منابع مشابه
A modified Wingate test for measuring anaerobic work of the upper body in junior rowers.
Eight elite junior oarsmen (ER) and sixteen club level rowers (CR) were tested for upper body strength (trunk, arms) and for mean, peak and minimum power outputs using the Double-Arm Anaerobic Work Test (DAAWT). This test is a modified version of the original Wingate test whereby athletes can be tested using trunk and both arms simultaneously. Multiple Discriminant Analysis was used to determin...
متن کاملModified Wingate Test for Measuring Anaerobic Work of the Upper Body in Junior Rowers
Eight elite junior oarsmen (ER) and sixteen club level rowers (CR) were tested for upper body strength (trunk, arms) and for mean, peak and minimum power outputs using the Double-Arm Anaerobic Work Test (DAAWT). This test is a modified version of the original Wingate test whereby athletes can be tested using trunk and both arms simultaneously. Multiple Discriminant Analysis was used to determin...
متن کاملDevelopment of a Specific Anaerobic Field Test for Aerobic Gymnastics
The current investigation aimed to develop a valid specific field test to evaluate anaerobic physical performance in Aerobic Gymnastics athletes. We first designed the Specific Aerobic Gymnast Anaerobic Test (SAGAT), which included gymnastics-specific elements performed in maximal repeated sprint fashion, with a total duration of 80-90 s. In order to validate the SAGAT, three independent sub-st...
متن کاملShort-term creatine supplementation has no impact on upper-body anaerobic power in trained wrestlers.
BACKGROUND Creatine (CR) is considered an effective nutritional supplement having ergogenic effects, which appears more pronounced in upper-body compared to lower-body exercise. Nevertheless, results regarding the impact of CR loading on repeated high-intensity arm-cranking exercise are scarce and in some cases conflicting. Interestingly, few of the conducted studies have structured their resea...
متن کاملUpper and Lower Body Anaerobic Muscular Power is Adversely Affected by Active Dehydration
Estimates of one in every 200 to 400 individuals, including the athletic population, suffer from celiac disease. Elite athletes present a unique complication when implementing a gluten-free diet because of the need for a high energy fuel. Dietetic adjustments such as increasing the caloric content and frequency are necessary to meet energy needs of highly physically active individuals. A Nation...
متن کاملWingate anaerobic test reference values for male power athletes.
PURPOSE The aim of this study was to develop reference values for the Wingate Anaerobic Test (WAnT) for peak power (PP), mean power (MP), and fatigue index (FI) in NCAA Division IA male athletes. METHODS Seventy-seven athletes (age 20.8±1.8 y, mass 84.4±9.4 kg, height 183.9±6.2 cm) participating in American football (n=52) and track and field (n=25) performed a 30-s WAnT resisted at 0.085 kp/...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 0 شماره 6
صفحات 1- 14
تاریخ انتشار 2013-10
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی برای این مقاله ارائه نشده است
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023