Design of High-Efficiency and Low-Cost Six-Phase Permanent Magnet Synchronous Generator for Direct-Drive Small-Scale Wind Power Application

نویسندگان

  • M. E. Moazzen Department of Electrical and Computer Engineering of Babol Noshirvani University of Technology, Babol, Iran.
  • M. Jafari-Nokandi Department of Electrical and Computer Engineering of Babol Noshirvani University of Technology, Babol, Iran.
  • S. A. Gholamian Department of Electrical and Computer Engineering of Babol Noshirvani University of Technology, Babol, Iran.
چکیده مقاله:

Permanent magnet synchronous generators (PMSG) have a huge potential for direct-drive wind power applications. Therefore, optimal design of these generators is necessary to maximize their efficiency and to reduce their manufacturing cost and total volume. In this paper, an optimal design of a six-phase 3.5 KW direct-drive PMSG to generate electricity for domestic needs is performed. The aim of optimal design is to reduce the manufacturing cost, losses and total volume of PMSG. To find the best design, single/multi-objective design optimization is carried out. Cuckoo optimization algorithm (COA) is adopted to solve the optimization problem. Comparison between the results of the single-objective and multi-objective models shows that simultaneous optimization of manufacturing cost, losses and total volume leads to more suitable design for PMSG. Finally, finite-element method (FEM) is employed to validate the optimal design, which show a good agreement between the theoretical work and simulation results.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis and Design of a Permanent-Magnet Outer-Rotor Synchronous Generator for a Direct-Drive Vertical-Axis Wind Turbine

In Permanent-Magnet Synchronous Generators (PMSGs) the reduction of cogging torque is one of the most important problems in their performance and evaluation. In this paper, at first, a direct-drive vertical-axis wind turbine is chosen. According to its nominal value operational point, necessary parameters for the generator is extracted. Due to an analytical method, four generators with differen...

متن کامل

Low-speed Permanent-magnet Synchronous Generator for Small-scale Wind Power Applications

Tendencies in development of wind power industry including direct-drive small-scale wind power plants and generators have been analyzed. Synchronous generators with permanent magnet excitation for direct-drive wind power turbines are described. Primary magnetic field distribution and effect of armature reaction have been studied for design of a low-speed multipole permanent-magnet synchronous g...

متن کامل

A Low-Speed, High-Torque, Direct-Drive Permanent Magnet Generator For Wind lhrbines

There is a market for small, efficient and costeffective wind generators for mini-grid and remote power systems. Direct-drive permanent magnet generators have become very attractive for this application. This paper describes the improvements achieved in an outer-rotor direct-drive permanent magnet generator by using finite element analysis and optimisation techniques. The starting torque of the...

متن کامل

A Permanent Magnet Generator for Small Scale Wind Turbines

This paper describes the development of a permanent magnet generator for small scale wind turbines. The generator has been designed for ease of manufacture so that it can be made by small mechanical engineering companies with limited electrical engineering knowledge. The generator has also been designed to have no cogging torque so that it can be used with all horizontal and vertical axis turbi...

متن کامل

A lightweight low speed permanent magnet electrical generator for direct-drive wind turbines

The evolution, design and test results of a novel permanent magnet generator for use in direct-drive wind turbines are presented. The novelty in the concept lies in the arrangement of electromagnetically active components – magnets, steel and copper – such that the structural mass can be reduced. It has also been designed such that during the assembly of large diameter permanent magnet machines...

متن کامل

Direct Liquid Cooling for an Outer-Rotor, Direct- Drive, Permanent-Magnet Synchronous Generator for Wind Farm Applications

Wind power is experiencing steady growth, and wind turbine technologies are continually developing. Currently, power ratings of up to 20 MW are being considered for future wind farms. Offshore applications, which call for the largest and most powerful wind turbines, demand a higher standard of reliability and maintainability. Because they offer better overall efficiencies and higher reliability...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 13  شماره 2

صفحات  152- 160

تاریخ انتشار 2017-06

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023