Design of Fuzzy Logic Based PI Controller for DFIG-based Wind Farm Aimed at Automatic Generation Control in an Interconnected Two Area Power System

نویسندگان

  • Arman Oshnoei Faculty of Electrical and Computer Engineering,Shahid Beheshti University,Tehran, Iran
  • Morteza Kheradmandi Faculty of Electrical and Computer Engineering,Shahid Beheshti University,Tehran, Iran
چکیده مقاله:

This paper addresses the design procedure of a fuzzy logic-based adaptive approach for DFIGs to enhance automatic generation control (AGC) capabilities and provide better dynamic responses in multi-area power systems. In doing so, a proportional-integral (PI) controller is employed in DFIG structure to control the governor speed of wind turbine. At the first stage, the adjustable parameters of the PI controller are optimized in an offline manner via the genetic algorithm (GA). In the second stage, the outlined fuzzy logic-based adaptive approach is intended for valid adjustment the gains values of PI controller through suitable membership functions in an online manner. To verify the high performance of the designed fuzzy PI controller, a hybrid interconnected two-area power system is considered, taking into account the physical limitations of generation rate constraint non-linearity and governor dead-band effect. Eventually, two scenarios including step and random load changes are selected to establish the success of the proposed fuzzy PI controller in damping of the area frequency and tie-line power oscillations. Simulation results are presented and compared with GA-based PI controller.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Generation Control Using LQR based PI Controller for Multi Area Interconnected Power System

The continuous time Linear Quadratic Regulator (LQR) theory has been implemented in the present work for the design of optimal Proportional Integral(PI) controller for the frequency response enhancement of multi area interconnected power system . The PI controller gains as proportional gain (Kp) and integral gain (Ki) are formulated as the optimal state-feedback gains, corresponding to the stan...

متن کامل

Load frequency control of two-area interconnected power system using fuzzy logic control approach

Power systems are composed of power units that are constantly connected to each other and the electric power flux is constantly moving between them. All systems must be implemented in such a way that not only under normal conditions but also unwanted inputs or disturbances, are applied. It also remains stable or returns to a stable name at the earliest possible time. The fundamental factors...

متن کامل

design of an analog fuzzy logic controller chip

fuzzy logic has been developed over the past three decades into a widely applied techinque in classification and control engineering. today fuzzy logic control is one of the most important applications of fuzzy set theory and specially fuzzy logic. there are two general approachs for using of fuzzy control, software and hardware. integrated circuits as a solution for hardware realization are us...

15 صفحه اول

Design of PI Controller for Automatic Generation Control of Multi Area Interconnected Power System using Bacterial Foraging Optimization

Naresh Kumari , Nitin Malik , A. N. Jha , Gaddam Mallesham #*4 # Department of Electrical, Electronics and Communication Engineering, The NorthCap University, Gurgaon, India 1 [email protected] 2 [email protected] * Ex-Professor, Electrical Engineering, Indian Institute of Technology, New Delhi, India 3 [email protected] #* Department of Electrical Engineering, Osmania University...

متن کامل

Hybrid Neuro Fuzzy Approach for Automatic Generation Control of Two -Area Interconnected Power System

The main objective of Automatic Generation Control (AGC) is to balance the total system generation against system load losses so that the desired frequency and power interchange with neighboring systems is maintained. Any mismatch between generation and demand causes the system frequency to deviate from its nominal value. Thus high frequency deviation may lead to system collapse. This necessita...

متن کامل

wind farm impact on generation adequacy in power systems

در سال های اخیر به دلیل افزایش دمای متوسط کره زمین، بشر به دنبال روش های جایگزین برای تامین توان الکتریکی مورد نیاز خود بوده و همچنین در اکثر نقاط جهان سوزاندن سوخت های فسیلی در نیروگاه های حرارتی به عنوان مهم ترین روش تولید توان الکتریکی مطرح بوده است. به دلیل توجه به مسایل زیست محیطی، استفاده از منابع انرژی تجدید پذیر در سال های اخیر شدت یافته است. نیروگاه های بادی به عنوان یک منبع تولید توان...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 07  شماره 03

صفحات  91- 95

تاریخ انتشار 2018-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023