Design of a generally applicable abdominal shield for reducing fetal dose during radiotherapy of common malignancies in pregnant patients

نویسندگان

  • A. Pourmoghadas
  • M. Atarod
چکیده مقاله:

Background: In most cancer cases, the treatment choice for a pregnant patient is radiotherapy. In these patients, the abdomen is usually not exposed therefore fetus exposure is due to peripheral dose (PD). The purpose of this study was to estimate the fetal dose (the maximum PD in each pregnancy stage) for modalities available and to fabricate and evaluate a generally applicable fetal shield. Materials and Methods: PD values were measured for brain, breast and mediastinum irradiation in a whole body anthropomorphic phantom using a NE 2571 ionization chamber. An external shield was then designed to reduce the fetal dose to the standard dose limit, 5 mSv. Results: The range of PD values as a function of distance from the field’s edge were as follows 1) 9.4-259 cGy for Mantel field 2) 6.5-95 cGy for chest wall irradiation with 10 MeV electrons, 3) 8.5- 52.5 cGy for tangential field with Co-60 and 4) 4.8-7.8 cGy for brain radiotherapy with 9 MV photon. PD values for the same setups using the fetal shield were as follows: 1) 1.4-22 cGy, 2) 0.5-4 cGy, 3) 1.5-5 cGy and 4) under 1 cGy. Conclusions: The measured PD data sets can be used to estimate fetal dose for specific treatment setups and pregnancy stages. The use of external shield designed in this research reduced the fetal dose effectively to under the threshold (a 70-90% reduction), except for the final stages of pregnancy in Hodgkin’s patients. Iran. J. Radiat. Res., 2012 10(3‐4): 151‐156

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

design of a generally applicable abdominal shield for reducing fetal dose during radiotherapy of common malignancies in pregnant patients

background: in most cancer cases, the treatment choice for a pregnant patient is radiotherapy. in these patients, the abdomen is usually not exposed therefore fetus exposure is due to peripheral dose (pd). the purpose of this study was to estimate the fetal dose (the maximum pd in each pregnancy stage) for modalities available and to fabricate and evaluate a generally applicable fetal shield. m...

متن کامل

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

A Phantom Study on Fetal Dose Reducing Factors in Pregnant Patients with Breast Cancer during Radiotherapy Treatment

PURPOSE This study aims to investigate the factors that reduce fetal dose in pregnant patients with breast cancer throughout their radiation treatment. Two main factors in a standard radiation oncology center are considered as the treatment planning systems (TPSs) and simple shielding for intensity modulated radiation therapy technique. MATERIALS AND METHODS TPS factor was evaluated with two ...

متن کامل

investigating the integration of translation technologies into translation programs in iranian universities: basis for a syllabus design in translation technology

today, information technology and computers are indispensable tools of any profession and translation technologies have become an indispensable part of translator’s workstation. with the increasing demands for high productivity and speed as well as consistency and with the rise of new demands for translation and localization, it is necessary for translators to be familiar with market demands an...

Assessment of Olfactory Threshold in Patients Undergoing Radiotherapy for Head and Neck Malignancies

Introduction: Radiotherapy is a common treatment modality for patients with head and neck malignancies. As the nose lies within the field of radiotherapy of the head and neck, the olfactory fibers and olfactory receptors may be affected by radiation. The aim of this study was to evaluate changes in olfactory threshold in patients with head and neck malignancies who have received radiation to th...

متن کامل

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 10  شماره None

صفحات  151- 156

تاریخ انتشار 2012-12

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023