Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

نویسندگان

  • Mohamad Yousefi Sooteh Medical Physics Department, Tabriz University of Medical Sciences, Tabriz, East Azerbaijan, Iran
  • Nader Riahi Alam Physics and Medical Engineering Department, Tehran University of Medical Sciences, Tehran, Iran
  • Sadegh Shurche Physics and Medical Engineering Department, Tehran University of Medical Sciences, Tehran, Iran
چکیده مقاله:

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlinearity of the applied gradient magnetic fields, the magnetic susceptibility of the imaged tissues, and chemical shift artifacts. Our goal is to design and construct a new Anthropomorphic Head Phantom for Assessment of Image Distortion in Treatment Planning Systems. Materials and Methods: In this study, CT scan images of head were transferred to the Mimic software (Mimics® Innovation Suite). Using this software, the skull texture was removed and a hollow layer formed between the bone tissue in which the bone tissue would be equivalent to the material. Then fabricated it with a 3D printer and used K2HPO4 (as bone). we designed a new 3D grid containing 13,824 reference features (control points) with AutoCAD software, fabricated it with a 3D printer, and filled it with gels that include nickel-doped agarose, sucrose, urea, and sodium chloride (as soft tissue) then placed this grid Inside the head phantom. The phantom is supplied with specially designed pads that allow fixation with any stereotactic frame or mounting for end-to-end testing. This phantom was tested on the Siemens 3 Tesla Prisma MRI model using a 64-channel head coil. We used imaging from a six-slice CT scan (Siemens) as a reference and matched the reference features in the MRI images with the CT-scan images. To achieve this, we used a three-dimensional reference feature model. Reproducibility on the phantom was investigated with three different imaging sessions per day for three different days. Results: The CT numbers and relative electron density of the gels closely resembled those of real tissue and T1 and T2 of the gels closely resembled those of real tissue. The geometric distortion in the 3D results was found to be due to field non-uniformity and nonlinearity of the gradients and its reproducibility. The mean Euclidean distance error for MRI volume was less than 0.9 mm. The maximum Euclidean error was 1.3 mm. Distortion in the whole volume is pronounced exclusively at the edges of the magnetic field. Conclusion: As with other investigations carried out in our work, the amount of distortion in the middle of the field was less than at its sides. This phantom can be used to check Image Distortion in Treatment Planning Systems.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Construction of an Equivalent Chest Homogeneous Phantom for Evaluation of Image Quality in Pediatric Radiography

Introduction: The purpose of this study is to build homogeneous equivalent phantom chest in order to provide the necessary ability for checking the image quality in radiographic tests in four age groups of children in terms of the most recent age group categorization ICRP103. This phantom provides the features of weakness and discrepancies similar to body and can be consi...

متن کامل

development and implementation of an optimized control strategy for induction machine in an electric vehicle

in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...

15 صفحه اول

diagnostic and developmental potentials of dynamic assessment for writing skill

این پایان نامه بدنبال بررسی کاربرد ارزیابی مستمر در یک محیط یادگیری زبان دوم از طریق طرح چهار سوال تحقیق زیر بود: (1) درک توانایی های فراگیران زمانیکه که از طریق برآورد عملکرد مستقل آنها امکان پذیر نباشد اما در طول جلسات ارزیابی مستمر مشخص شوند; (2) امکان تقویت توانایی های فراگیران از طریق ارزیابی مستمر; (3) سودمندی ارزیابی مستمر در هدایت آموزش فردی به سمتی که به منطقه ی تقریبی رشد افراد حساس ا...

15 صفحه اول

Design and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems

Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...

متن کامل

an investigation into iranian teachers consistency and bias in evaluation of students writings

while performance-based language assessment has led to an increased authenticity and content validity in the practice of writing assessment, the reliability of ratings has become a major issue. research findings have shown different reactions by native english speaker (nes) and non-native english speaker (nns) teachers to students’ writings. the focus of this study is on investigating whether i...

application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples

ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  108- 108

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023