Design and Simulation of Hot Cathode Ionization Vacuum Gauge with no X-Ray Limitations
نویسندگان
چکیده مقاله:
In this paper, the MEMS type ionization gauge with no X-Ray limitations has been presented. Having the dimensions of 2.4 mm× 0.8mm × 1.4 mm, the designed gauge is 9000 times smaller than the conventional type and can operate in HV and UHV pressures up to 5×10-9 torr. Operating at the temperature of 750°C, the cathode of proposed gauge is implemented using nickel and works in a way in which its temperature, independent of the peripheral gas pressure, remains constant throughout it. The total power consumption of the designed scheme is 430 times less than the conventional type. The electrical, thermal, mechanical, ionization collisions and elastic collisions have been performed using COMSOL5 program, and the output data from COMSOL were analyzed by MATLAB. The simulation results have been employed in implementation of cathode and other parts’ dimensions and based on these results the sensitivity factor of 0.2 1/torr was obtained.
منابع مشابه
simulation and design of electronic processing circuit for restaurants e-procurement system
the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...
15 صفحه اولDesign and Simulation of an X Band LC VCO
In this paper, a systematic method for the circuit parameters design of a monolithic LC Voltage Controlled Oscillator (VCO) is reported. The method is based on the negative resistance generation technique. As a result, a VCO has been designed in 0.18um CMOS technology using a conventional VCO structure to obtain the optimum values for the phase noise and power consumption. The simulation result...
متن کاملX-ray Emission Accompanying Cathode Microdischarge
Electrical discharge in vacuum is accompanied by X-ray radiation. Knowledge of the generation mechanism of radiation may lead to its practical use. The analysis of this phenomenon indicates that it is only at the discharge development phase until the moment of the anode plasma generation that the proper conditions for X-ray generation are satisfied. The intensity of radiation is dependent on th...
متن کاملsimulation and comparison of radiology x-ray spectra
monte carlo method is a very accurate method to optimize medical diagnostic radiology spectra and simulation of radiation transportation. using mcnp code, radiology and mammography attenuated x-rayspectraweresimulated.the ipem report number 78 was used as a reference to compare with the geant4 and mcnp simulations because of its popularity and wide availability. the results of geant4 in 40kev s...
متن کاملX-ray Images of Hot Accretion Flows
We consider the X-ray emission due to bremsstrahlung processes from sphericallysymmetric low radiative-efficiency hot accretion flows around supermassive and galactic black holes. We calculate surface brightness profiles and Michelson visibility functions for a range of density profiles, ρ ∼ r−3/2+p, with 0 < p < 1, to allow for the presence of outflows. We find that although the 1 keV emitting...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 31 شماره 11
صفحات 1883- 1892
تاریخ انتشار 2018-11-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023