Design and Fabrication Process of MTF Phantom CT Scan
نویسندگان
چکیده مقاله:
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan images is to calculate MTF chart. Modulation in imaging is means contrast and the transfer function to the concept of the contrast ratio of the output to the contrast of the input system. The modulation transfer function of an imaging system is reflecting the contrast of the system at various space frequencies. The aim of this study is created phantom MTF for a CT scan. Materials and Methods: For phantom design, firstly, the number of pairs of lines required for CT scan images was evaluated and 2 to 14 LP/cm were selected for this phantom. Then, to create these pair of lines, you need a metal with a low atomic number until the amount of artifact decreases that aluminum was selected in this regard. Then using the AutoCAD software, the MTF calculation tool was designed as L-shape. Finally, the MTF calculation tool was combined into the groove created in the acrylic disk using the LOEXAL glue. Results: This phantom was tested for various CT scan devices. The results obtained from this phantom are equal to the external samples. The MTF chart obtained from this phantom corresponds to the MTF Phantom Pro-CT chart. Conclusion: This phantom has much less weight than other phantoms. The thickness of these lines is high and it can be captured in a slide CT scan of all the lines. In this phantom, the modulation function or MTF is calculated with high precision and more points. This phantom can be used for limiting spatial resolution.
منابع مشابه
Design and Fabrication Process of CT number Linearity and Homogeneity Phantom CT Scan
Introduction: One of the most valuable goals of phantoms, replacing with human goals in the field of research and quality control of diagnostic X-ray systems. There are various algorithms and methods for obtaining Homogeneity and CT number linearity for CT scan device. One of the most famous of these methods, the method is to use a uniform and homogeneous environment to comput...
متن کاملa study on the design of bio-ethanol process from date wastes of sistan and baluchistan province
اتانول کاربردهای متنوعی در صنایع لاستیک سازی، رنگسازی، حلالها ومکمل سوخت خودرو دارد. اتانول برخلاف نفت از جمله مواد تجدیدپذیر محسوب می شود که مشکلات زیست محیطی و آلودگی نیز ایجاد نمی کند. استفاده از اتانول به عنوان مکمل سوختخودروها از جمله مهمترین مصارف صنعتی این ماده بشمار می رود. با توجه به این موضوع تحقیق و توسعه در زمینه تولید اتانول با درجه خلوص بالا در سطح جهان، و نه تنها در کشور های پیشر...
Design and Fabrication of an Improved Single-Column Chromatographic Separation Process
In this work, an improved single-column chromatographic (ISCC) separation process is proposed. The term `improved' refers to both conceptual and physical modifications compared to the available single-column processes, including a novel fraction collection scheme and allowing overlapped peaks from adjacent cycles. Also the fraction collection mechanism was modified in order to facilitate online...
متن کاملDesign and fabrication of three axes accelerometer
Technology can provide safety in physical practices and improving the performance of these activities, so manufacturing of equipments for these purposes has been considered widely. The aim of the present paper was design and fabrication of three-axis accelerometer. hree acceleration sensors, three gyroscopes for angular velocity measurement, a microcontroller for converting analog data to ...
متن کاملDesign and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging
Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 100- 100
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023