Design and Fabrication Process of CT number Linearity and Homogeneity Phantom CT Scan
نویسندگان
چکیده مقاله:
Introduction: One of the most valuable goals of phantoms, replacing with human goals in the field of research and quality control of diagnostic X-ray systems. There are various algorithms and methods for obtaining Homogeneity and CT number linearity for CT scan device. One of the most famous of these methods, the method is to use a uniform and homogeneous environment to compute Homogeneity and as well as the use of different materials with different densities to calculate CT number linearity. Therefore, a phantom was invented for a simple and fast calculation of Homogeneity and CT number linearity parameters for CT scan devices. Materials and Methods: Construction of Phantom CT number Homogeneity: To make this phantom has been used CNC three-axis machine model 2000. First, an acrylic tube is cut with an internal diameter of 154 mm and an external diameter of 160 mm and a length of 30 mm. Then two acrylic disks are cut with a diameter of 154 mm and a thickness of 5 mm. In the middle of one of these disks hole is created a 20 mm diameter, which is filled with a plastic screw. Then these two acrylic disks are attached to the beginning and end of the tube. Construction of Phantom CT number linearity: For make this phantom has been used CNC three-axis machine model 2000. Using this device, the PE (Polyethylene), PMMA (Acrylic), PTFE (Teflon), Air, PS (Polystyrene) and PA (Polyamide) rods are cut in 25 mm and 25 mm in length. Then an acrylic disk is cut diameter of 154 mm and a thickness of 5 mm. Results: This phantom was tested for various CT scan devices. The results obtained from this phantom are equal to the external samples. The CT number Linearity chart obtained from this phantom corresponds to the CT number Linearity Phantom Pro-CT chart. Conclusion: This phantom has much less weight than other phantoms. The amount of material used in this phantom is greater than the other similar phantoms. The price of this phantom is very low compared to similar samples. In this phantom, Homogeneity and CT number linearity are calculated with higher precision and more points. Also, this phantom can be used to calculate noise.
منابع مشابه
Design and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملThe influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...
متن کاملContrast-Induced Nephropathy Following CT Scan and Its Associated Factors
Background and purpose: Contrast-induced nephropathy (CIN) as a common complication of administration of contrast media (CM) is a major source of hospital morbidity and mortality. The aim of this study was to determine the incidence of CIN after contrast-enhanced CT scan and identifying the related risk factors. Materials and methods: A cross-sectional study was carried out in 100 patients att...
متن کاملconstruct and predictive validation of english language teachers competency test (elt-ct
یافتن اعتبار سازه ای و پیشگویانه تست با استفاده از,efa.
15 صفحه اولa study on the design of bio-ethanol process from date wastes of sistan and baluchistan province
اتانول کاربردهای متنوعی در صنایع لاستیک سازی، رنگسازی، حلالها ومکمل سوخت خودرو دارد. اتانول برخلاف نفت از جمله مواد تجدیدپذیر محسوب می شود که مشکلات زیست محیطی و آلودگی نیز ایجاد نمی کند. استفاده از اتانول به عنوان مکمل سوختخودروها از جمله مهمترین مصارف صنعتی این ماده بشمار می رود. با توجه به این موضوع تحقیق و توسعه در زمینه تولید اتانول با درجه خلوص بالا در سطح جهان، و نه تنها در کشور های پیشر...
Evaluation of Diagnostic Value of CT Scan and MRI in Brain Tumors and Comparison with Biopsy
Abstract Background Cerebral neoplasm arises from brain, spinal cord and meningeal cells. Not only malignant cerebral neoplasm also benign tumor could lead to death due to mass effect on vital structures. Access to these tumors is difficult, and MRI and CT scan could be helpful in determining anatomical location of tumors and distinction of malignant from benign. Objective For better and ea...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 96- 96
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023