Design and Fabrication of PVC Membrane Electrode Based on Netural Ligand (E)-N'-(1-(2-Hydroxyphenyl)Ethylidene)Benzohydrazi for Teramadol hydrochloride Measurement in Drugs and Biological Fluids
نویسندگان
چکیده مقاله:
Here, a simple, quick, Low cost and sensitive Potentiometric method is described for tramadol hydrochloride measurement using .PVC membrane electrode based on neutral ligand (E)-N'-(1-(2-hydroxyphenyl)ethylidene)benzohydrazid. Besides, effect of various parameters like ionic additives, membrane solvent and pH on the Potentiometric response of the electrode are investigated. The best electrode performance was observed with membrane composition of PVC 30%, DBP60%, carrier 7% and additive3% within pH range of 3-6. This electrode showed Nernstian slope about -60.24±0.2 mV/dec, detection limit of 1.75×10-6 M and response time about 15 sec over the concentration range of 1.0×10-1 to 3.16×10-6 M. The lifetime of electrode was about 40 days. Finally, by using the electode in measuring the amount of tramadol hydrochloridein urine, cow’s milk, and tablet utilizing calibration curve and method of standard addition, the electrode performance and behavior are investigated. The results showed the mentioned electrode had more appropriate performance than other usual approaches.
منابع مشابه
Manganese (M-selective PVC membrane electrode based on N-(2- picolinamido ethyl)-Picolinamide as ionophore
In this research, a PVC membrane electrode for Manganese (II) ions based on N-(2-Picolinamidoethyl)Picolinamide as neutral carrier was prepared. The electrode exhibits a Nemstian responseover Mn(II) concentration range of (1.0 x10-5 t01.0 X 10-1M) with a slope of 29.3±0.5 mV perdecade of concentration with a working pH range of 4.0-9.0. It has a fast response time (
متن کاملfabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions
a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...
simulation and design of electronic processing circuit for restaurants e-procurement system
the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...
15 صفحه اولmanganese (m-selective pvc membrane electrode based on n-(2- picolinamido ethyl)-picolinamide as ionophore
in this research, a pvc membrane electrode for manganese (ii) ions based on n-(2-picolinamidoethyl)picolinamide as neutral carrier was prepared. the electrode exhibits a nemstian responseover mn(ii) concentration range of (1.0 x10-5 t01.0 x 10-1m) with a slope of 29.3±0.5 mv perdecade of concentration with a working ph range of 4.0-9.0. it has a fast response time (
متن کاملPotentiometric determination of Benzydamine hydrochloride using PVC membrane and coated wire sensors in pure form, pharmaceutical compounds and biological fluids
The construction and electrochemical response characteristics of PVC membrane and coated wire sensors for the determination of Benzydamine hydrochloride (Benz) are described. PVC membrane sensors, include sensors 1, 2 and 3, and coatedwire sensors include sensors 4, 5 and 6. Sensors 1 and 4 based on benzydamine phosphotungstate (Benz-PTA) as ion-pair, sensors 2 and 5 based on benzydamine phosph...
متن کاملThiocyanate ion-selective PVC membrane electrode based on N,N'-ethylene-bis(4-methylsalicylidineiminato)nickel(II).
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on an N,N'-ethylene-bis(4-methyl-salicylidineiminato) nickel(II) [Ni(EBMSI)] complex as a carrier for a thiocyanate-selective electrode is reported. The influences of the membrane composition, pH and possible interfering anions were investigated based on the response properties of the electrode. The electrode exhibited a goo...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 5 شماره 2
صفحات 285- 295
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023