Design and Fabrication of a Portable 1-DOF Robotic Device for Indentation Tests

نویسندگان

  • Farshid Najafi School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
  • Masoud Moeinzadeh School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
  • Mojtaba Haghighi School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
  • Sheyda Davaria School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
چکیده مقاله:

There are many tactile devices for indentation examinations to measure mechanical properties of tissue. The purpose of this paper is to develop a portable indentation robotic device to show its usability for measuring the mechanical properties of a healthy abdominal tissue. These measurements will help to develop suitable mathematical models representing abdominal tissue. A 1-DOF portable robotic device has been designed to be placed on the patient’s body. The device presses sensor plate on the abdomen. Force and position sensors measure the indentation force and displacement, respectively. Due to tissue time-dependent behavior, linear viscoelastic models with three, five and seven parameters have been selected for mathematical modeling. Nonlinear Least Squares (NLS) method is adopted to fit viscoelastic models with experimental data obtained from stress relaxation tests. Using Finite Prediction Error (FPE) criterion, viscoelastic model with five parameters has been selected as the optimal model. The results of the present paper can be used in abdominal tissue simulators to facilitate teaching palpation examinations.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Fabrication of a Microwave Weed Killer Device for Weed Control Applications

In this paper, the design and the results of a microwave radiation system for agriculture applications is discussed. The system is fabricated and successfully tested on weed seeds. The device, which uses a commercial 1 kW magentron, proved to be effective for preventing the germination control of popular weeds of Iran. Seven weed species were tested separately by using this system and then the ...

متن کامل

Design and Fabrication of Ultralight High-Voltage Power Circuits for Flapping-Wing Robotic Insects

Flapping-wing robotic insects are small, highly maneuverable flying robots inspired by biologicalinsects and useful for a wide range of tasks, including exploration, environmental monitoring, searchand rescue, and surveillance. Recently, robotic insects driven by piezoelectric actuators have achievedthe important goal of taking off with external power; however, fully autonomous operation requir...

متن کامل

A one-DOF freehand haptic device for robotic tele-echography.

Tele-echography may be an interesting alternative to conventional care when the medical expert is not close to the patient to be examined. In a system for tele-echography, medical expert proprioception and gesture feelings must be preserved to synchronize the ultrasound images with the motion made by the physician. It is why we develop a master-slave system for robotic tele-echography integrati...

متن کامل

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

Fabrication of a Cell Fixation Device for Robotic Cell Microinjection

Automation of cell microinjection greatly reduces operational difficulty, but cell fixation remains a challenge. Here, we describe an innovative device that solves the fixation problem without single-cell operation. The microarray cylinder is designed with a polydimethylsiloxane (PDMS) material surface to control the contact force between cells and the material. Data show that when the injectio...

متن کامل

Draft: Design and Fabrication of a Soft Robotic Direct Cardiac Compression Device

A direct cardiac compression (DCC) device is an active sleeve that is surgically placed around the heart to help the failing heart to pump without contacting blood. Soft robotic techniques enable fabrication of a conformable DCC device containing modular actuators oriented in a biomimetic manner that can restore the natural motion of the heart and provide tunable active assistance. In this pape...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 49  شماره 1

صفحات  179- 188

تاریخ انتشار 2018-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023