Cyclic Voltammetry of Cobalt Chloride with L- Carrageenan (LK) Using Glassy Carbon Electrode
نویسندگان
چکیده مقاله:
The redox behavior cobalt chloride was studied voltammetrically in presence and absence of L- Carrageenan (LK) natural polymer using glassy carbon electrodes in 0.1 M KCl supporting electrode. Scan rates are studied for the redox behaviors for CoCl2 alone or in presence of L- Carrageenan (LK) natural polymer. Stability constants for the interaction of cobalt ions with L - Carageenan (LK) natural polymer are evaluated. All mechanisms are discussed.The redox behavior cobalt chloride was studied voltammetrically in presence and absence of L- Carrageenan (LK) natural polymer using glassy carbon electrodes in 0.1 M KCl supporting electrode. The interaction of CoCl2 with L-Carrageenan (LK) has been studied using cyclic voltammetry technique in the potential range (+1.5 to -1.0) V at different scan rates in water at 292.15 oK using KCl (0.1M) as supporting medium and glassy carbon as a working electrode. The study is valuable for evaluating the thermodynamic properties [3-18]. The cobalt ions used show two oxidation peak at 0.02 and 0.06 V and two reduction peaks at 0 and -0.7 V These two peaks corresponding to the oxidation of cobalt zero valent to monovalent and then the oxidation of cobalt monovalent to divalent cobalt Scan rates are studied for the redox behaviors for CoCl2 alone or in presence of L- Carrageenan (LK) natural polymer. Stability constants for the interaction of cobalt ions with L - Carageenan (LK) natural polymer are evaluated. All mechanisms are discussed.
منابع مشابه
Cyclic voltammetry of bulk and nano manganese sulfate with Doxorubicin using glassy Carbon electrode
The cyclic voltammetry of both bulk manganese sulfate (BMS) and nano manganese sulfate (NMS) were studied using 0.1M KCl supporting electrolyte and glassy carbon working electrode. The redox behavior for both bulk (BMS) and MnSO4 (NMS) sulfate was studied voltammetrically in presence and absence of Doxorubicin (DR) using three electrodes system, silver- silver chloride (Ag/AgCl), pla...
متن کاملCyclic voltammetry of bulk and nano manganese sulfate with Doxorubicin using glassy Carbon electrode
The cyclic voltammetry of both bulk manganese sulfate (BMS) and nano manganese sulfate (NMS) were studied using 0.1M KCl supporting electrolyte and glassy carbon working electrode. The redox behavior for both bulk (BMS) and MnSO4 (NMS) sulfate was studied voltammetrically in presence and absence of Doxorubicin (DR) using three electrodes system, silver- silver chloride (Ag/AgCl), pla...
متن کاملElectrochemical Chiral Recognition of Naproxen Using L-Cysteine/Reduced Graphene Oxide Modified Glassy Carbon Electrode
The electrochemical response of S- and R-naproxen enantiomers was investigated on L-cysteine/reduced graphene oxide modified glassy carbon electrode (L-Cys/RGO/GCE). The production of the reduced graphene oxide and L-cysteine on the surface of the glassy carbon electrode was done by using electrochemical processes. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were us...
متن کاملGeobacter sulfurreducens biofilms developed under different growth conditions on glassy carbon electrodes: insights using cyclic voltammetry.
Growth of biofilms of G. sulfurreducens on glassy carbon that yield a bioelectrocatalytic response to acetate oxidation is achieved using a fixed applied potential, with current density for acetate oxidation scaling with applied potential. In contrast biofilms grown under electron acceptor-limiting conditions display redox signals shifted to lower potentials and do not oxidise acetate.
متن کاملEvaluation of a Nafion Coated Glassy Carbon Electrode for Determination of Paraquat by Differential Pulse Voltammetry
Este trabalho apresenta uma avaliação de um eletrodo de carbono vítreo recoberto com filme de Nafion para a determinação de paraquat em águas de rio e urina por voltametria de pulso diferencial. O filme foi formado adicionando-se 4 μL de uma solução de Nafion 4% (m/v) na superfície do eletrodo, seguindo-se evaporação do solvente com luz infra-vermelha. A máxima relação sinal/ruído foi obtida em...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 14 شماره 4
صفحات 90- 99
تاریخ انتشار 2017-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023