Cu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone

نویسندگان

  • E. Baghdar -
  • M. Aghaie -
  • M. Giahi -
  • M. H. Fekri -
  • S. Farhadi -
چکیده مقاله:

In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. The limit of detection was 1.010-6 M. The response time of the electrode is about 15s and can be used for more than 2 month without any divergence in potential.    The proposed sensor showed fairly a good discriminating ability towards Cu(II) ion in comparison to other ions. The practical application of the electrode was tested by using it as an indicator electrode to determine the end point in the potentiometric titration of Cu(II) with EDTA solution.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

cu(ii) ion- selective membrane electrode based on bis(n-salicylidene-3,3'-diamino diphenyl) sulfone

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

متن کامل

cu(ii) ion- selective membrane electrode based on bis(n-salicylidene-3,3'-diamino diphenyl) sulfone

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

متن کامل

Thermodynamic study of Cu(II) ion-selective membrane electrode based on his (N-salicylidene-3,32-diamino dip hen y sulfone

The effect or temperature on the behavior of Cu(II) Mr electrode based on bis(N-sahcylidenc-3.3'-4iaminodiphenyl) sulfune(BSDDS) was studied. This electrode showed a good Nemstian response in the temperaturerange of 20-50 C. Also, the behavior of the synthesized electrode was inngigated in the mixed solvents'ethanol+water" and "dioxane +water'.

متن کامل

Steroid acid amides of diamino diphenyl sulfone.

For the past several years, I synthesized various new steroid compounds and steroid derivatives for chemotherapeutic purposes. The series of the steroid acid amides of diamino diphenyl sulfone included 4-cholylamino4’-amino diphenyl sulfone (B 110) and 4-desoxycholylamino 4’-amino diphenyl sulfone (Bill) which were chosen among representative members cf this group for more detailed study. A bri...

متن کامل

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

Sn (II) Ion- Selective Membrane Electrode based on Dibenzo-18-Crown-6

We found that dibenzo-18-crown-6 (DB18C6) can be used as an ionophore to make a tin (II)-ionselectivemembrane electrode. The electrode exhibits a near Nernstian response for Sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27.5 ± 0.6 mV per concentration decadein an acidic solution (pH=1). The limit of detection was 8.0× 10-7 M. It has a response time of < 20s an...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 4  شماره 1

صفحات  57- 62

تاریخ انتشار 2007-04-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023