Construction of an Ion-Selective Eelectrode for Determination of permanganate Ion

نویسندگان: ثبت نشده
چکیده مقاله:

A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential response of the proposed sensorwere investigated. The electrode exhibited a sub-Nernstian slope of 51.0±1.0 mV per decade for MnO4- over aconcentration range of 3.3×10-6-7.5×10-2 M in the pH range 5.0-10.0. The detection limit and response time ofthe electrode were 1.7×10-6 M and 14 s, respectively. The electrode can be used within 3 days without anyconsiderable divergence in its potential. This electrode was successfully employed for indirect determinationof Mn(II).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

construction of an ion-selective eelectrode for determination of permanganate ion

a pvc ion-selective membrane electrode based on cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of mno4- ion. this electrode revealed good selectivity toward permanganate ion over a widevariety of anions. effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...

متن کامل

Ion Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation

Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The...

متن کامل

application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples

ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...

15 صفحه اول

An Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions

In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...

متن کامل

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

Determination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore

A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 1  شماره 1

صفحات  8- 14

تاریخ انتشار 2010-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023