Construction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)
نویسندگان
چکیده مقاله:
In the present study, a simple electrochemical sensor for trace determination of Hg(II) ions in aqueous solutions was introduced. The proposed sensor was designed by incorporation of the 4-methyl-piperidine-carbodithioate capped gold nanoparticles (GNPs) into the carbon paste electrode (CPE), which provides a remarkably improved sensitivity for stripping voltammetric determination of Hg(II). Differential pulse voltammetry (DPV) was applied for quantitative determinations. The resulting electrode exhibited a linear relationship towards Hg(II) concentrations ranging from 0.4 to 100.0 μg L-1. The detction limit was found to be 0.2 μg L-1 (S/N = 3) that is lower than the permitted value of Hg(II) reported by the Environmental Protection Agency (EPA) limit for drinkable water. The relative standard deviation (RSD) for 7 successive measurements at different electrodes was also found to be 3.8%. The interference studies showed that the several common metal ions did not interfere with the quantitative mercury determination. The designed sensor was further utilized for the determination of mercury ions in real water samples with satisfactory results.
منابع مشابه
application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples
ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...
15 صفحه اولPotentiometric determination of trace amounts of amantadine using a modified carbon-paste electrode.
A chemically modified carbon-paste electrode has been described for the sensitive and selective determination of amantadine. Beta-cyclodextrin was used as modifier. The electrode shows a sub-Nernstian response of 51.0 +/- 1.0 mV decade(-1) for amantadine in the concentration range of 6.3 x 10(-10)-7.1 x 10(-7) M at 25 degrees C. The optimum pH value was maintained at 4.5 using a 0.02 M acetate ...
متن کاملSelective Potentiometric Sensor for Isoniazid Ultra-Trace Determination Based on Fe3O4 Nanoparticles Modified Carbon Paste Electrode (Fe3O4/CPE)
Significant effects of magnetic iron oxide (Fe3O4) nanoparticles on the potentiometric behavior of carbon paste electrode for bio determination of Isoniazid aromatic drug (INH) were studied. The electrochemical performance of modified Fe3O4/CPE was investigated. The constructed Fe3O4/CPE showed high precision, sensitivity ...
متن کاملAlumina nanoparticles modified carbon paste electrode as a new voltammetric sensor for determination of dopamine
The present study examines a new dopamine sensor based on Alumina nanoparticles modified carbon paste electrode (Al2O3NPsCPE). Moreover, the present study focuses on the electrochemical act of the Al2O3NPsCPE for the detection of dopamine by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). There is also a focus on the specification of the prepared modified electrode by electroc...
متن کاملA Novel Carbon Paste Electrode for Potentiometric Determination of Vanadyl Ion
Carbon paste electrode was modified by disodium 2,4-diamino-7-methylbenzo[g] pteridine-5,10-dioxide to fabricate a sensor for potentiometric determination of vanadyl ion (VO2+) in aqueous medium. The new ligand was synthesized in three steps with high yield. The optimal composition of the carbon paste was made of graphite powder (64.5%), ionophore (16.6%), paraffin oil (17.8%), a...
متن کاملapplication of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 6 شماره 1
صفحات 1- 12
تاریخ انتشار 2019-06-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023