Consideration of accurate dose distribution for Contura balloon catheter in breast brachytherapy with MCNP5 simulation

نویسندگان

  • Maryam Papie Nuclear Engineering Department, School of Mechanical Engineering, Shiraz University, Shiraz, Iran
  • R Faghihi Nuclear Engineering Department, School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
  • S Sina
چکیده مقاله:

Introduction: Contura is a balloon applicator that used to deliver intra cavity radiation for Partial Breast Irradiation (PBI) treatments. Contura with 4 peripheral lumens surrounding the central, for loading HDR sources from an after loader system can provide an asymmetric dose distribution and gives a more flexible shape of dose than earlier balloon applicators such as Mammo site. Accurate dosimetry is necessary to avoid deviations in delivered dose from that prescribed for a successful treatment. In this study we tried to explore possible uncertainties in simple water phantom measurements compared to the realistic breast cancer treatment condition with Contura. Materials and Methods: MCNP5 simulations were performed to have investigations on dose distribution. Several trials have been introduced to study the effects of corrections for phantom geometry and content. First, dose distributions were considered for an ICRU-44 breast phantom and the obtained results were compared with water. In next trial geometry was corrected to take the effects of an air cavity as lung inside the chest into account. Investigations were followed in third trial with correction at the breast skin surface to evaluate tissue-air interferences at skin. 192-Ir HDR sources were simulated on 7 dwell positions on each lumen. Lumens were defined inside a water sphere as saline filled balloon. Results have presented as dose distribution plots in breast and dose volume histogram analysis for PTV. Results: The ICRU-44 breast phantom demonstrated differences less than 1% in breast from water. Air cavity as the lung tissue has not shown significant effects on dose distribution in the breast, but correction at skin surface has caused up to 5% overestimations proximity near this area. However almost in other places in the corrected breast, the matched results to the water phantom have been observed. Conclusion: The results of this investigation indicate no significant deviations from a water phantom without any corrections. Therefore, treatment planning systems can still be used without significant uncertainties in treatment of breast cancer using HDR brachytherapy with Contura device. Differences can be corrected to provide a precise dosimetry but because of underestimated values obtained in water phantom dosimetry it can be a conservative approximation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proof of Symmetric Dose Distribution in Mammosite Applicator in Breast Brachytherapy with MCNP Simulation

Introduction: In brachytherapy treatments, high-dose sources are used in interstitial placement. In this paper, the modeling of a common breast cancer treatment applicator called MammoSite is done by the Monte Carlo simulation code. Then, to study and calculate the amount of doses in the breast and the dose rate of the organs at risk of radiation, including: lungs, ribs and ski...

متن کامل

Dosimetric Improvements in Balloon Based Brachytherapy Using the Contura® Multi-Lumen Balloon (MLB) Catheter to Deliver Accelerated Partial Breast Irradiation

PURPOSE Preliminary dosimetric findings in patients managed with the Contura® Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) on a multi-institutional phase IV registry trial were reviewed. MATERIAL AND METHODS CT-based 3D planning with dose optimization was performed for all patients. For the study, new ideal dosimetric goals w...

متن کامل

The Effect of Breast Phantom Material on the Dose Distribution in AccuBoost Brachytherapy

Introduction: Long-term teletherapy program is not suitable for old and working patients and those living in areas where little access to primary health care is available. Accelerated partial breast irradiation (APBI) using high dose rate (HDR) brachytherapy is an appropriate alternative for these patients due to its limited number of fractions. The AccuBoost is a system for delivering APBI. Th...

متن کامل

Dose modification factor analysis of multilumen balloon brachytherapy applicator with Monte Carlo simulation

The Contura brachytherapy applicator is a silicone balloon with five lumens in which a high-dose-rate brachytherapy source can traverse. Multilumen applicators, like the Contura, are used in accelerated partial breast irradiation (APBI) brachytherapy in instances where asymmetric dose distributions are desired; for example, when the applicator surface-to-skin thickness is small (< 7 mm). In the...

متن کامل

Skin and chest wall dose with multi-catheter and MammoSite breast brachytherapy: Implications for late toxicity.

PURPOSE Accelerated partial breast irradiation (APBI) continues to increase in popularity. Up to 14% of patients treated with the MammoSite (MS) report some degree of chronic pain, which may be related to chest wall toxicity. Reports from several institutions using the multicatheter (MC) technique have not shown associated elevated chest wall toxicity. Additionally, a recent investigation has s...

متن کامل

Dosimetric evaluation of multilumen intracavitary balloon applicator rotation in high‐dose‐rate brachytherapy for breast cancer

The objective of this work is to evaluate dosimetric impact of multilumen balloon applicator rotation in high-dose-rate (HDR) brachytherapy for breast cancer. Highly asymmetrical dose distribution was generated for patients A and B, depending upon applicator proximity to skin and rib. Both skin and rib spacing was ≤ 0.7 cm for A; only rib spacing was ≤ 0.7 cm for B. Thirty-five rotation scenari...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  153- 153

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023