Confirming nasogastric tube position: methods & restrictions: A narrative review
نویسندگان
چکیده مقاله:
Background and Purpose: Inserting a nasogastric tube, though a common clinical procedure with widespread use for critically ill patients, can produce unexpected complications so that tube misplacement into the lungs is a potential complication with serious consequences. The reliability of common bedside methods to differentiate between pulmonary and gastric placement has not been acceptable. The goal of this study was to review the diagnostic accuracy of methods in detecting inadvertent airway intubation and verifying correct placement of nasogastric tube and restrictions. Methods: A review of Pub Med, Medline and CINAHL databases has been conducted to identify peer-reviewed, English language, human subject research studies published between the years 1994 and 2013.The research was conducted on the confirmation, methods and restrictions of NGT in the adult's population. Out off 151 English publications, 29 were duplicates and 2 were animal studies. Quality assessments, data extractions and analysis were completed on all included studies. Results: Although methods for assessing correct NGT location at the bedside are available, each has its limitations. The methods include auscultation (the most common method), PH testing of aspirates, capnography, insertion under direct vision and magnetic detection. All studies used X-rays as the reference standard for comparison since auscultation is unreliable. Conclusion: While none of the existing bedside methods for testing the position of nasogastric tubes is totally reliable, the evidence suggest that using more than one method for confirmation of nasogastric tube position is necessary.
منابع مشابه
confirming nasogastric tube position: methods & restrictions: a narrative review
background and purpose: inserting a nasogastric tube, though a common clinical procedure with widespread use for critically ill patients, can produce unexpected complications so that tube misplacement into the lungs is a potential complication with serious consequences. the reliability of common bedside methods to differentiate between pulmonary and gastric placement has not been acceptable. th...
متن کاملConfirming the position of a nasogastric tube - what does the literature say?
Nasogastric tubes are a medical device that can be used for a number of purposes. The process of inserting them however can be complicated. Nurses must therefore use an evidencebased approach to confirm the correct position of nasogastric tubes and there are three main techniques described in the literature to do so. To date, one group of authors has published the majority of the studies on the...
متن کاملCase report and review – Nasogastric tube complications
The placement of nasogastric (NG) tubes is an extremely common intervention in general surgical wards and intensive care units. We report a case series of two patients who developed life threatening complications from the insertion of nasogastric tubes. Case 1 was a 71 year old man admitted to the Intensive Care Unit with pancreatitis who had three isolated complications from NG tube insertion....
متن کاملUsing pH testing to confirm nasogastric tube position.
In 2004 the MHRA published a directive for all hospitals in the UK to use pH paper in place of litmus paper when testing position of nasogastric tubes (NGT). This article illustrates one trust's implementation of this process of change in order to achieve compliance.
متن کاملConfirming placement of nasogastric feeding tubes.
A 78-year-old alert woman in hospital was being fed through a nasogastric tube because of deconditioning. She was taking acetylsalicylic acid for ischemic cardiomyopathy, and a vitamin K antagonist for atrial fibrillation and a recent axillobifemoral bypass thrombosis. She had a permanent right-side nephrostomy after receiving an injury to the ureter during the bypass surgery. She did not have ...
متن کاملA malfunctioning nasogastric feeding tube.
A critical point of nasogastric feeding tube placement, potentially resulting in an unsafe and/or non-effective operation of the device, is the monitoring of its proper placement into the stomach. A properly obtained and interpreted radiograph is currently recommended to confirm placement. We reported the case of a 68-year-old demented woman referred for complicated dysphagia. A nasogastric tub...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 2 شماره None
صفحات 55- 62
تاریخ انتشار 2015-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023